A New Screen-printed Ion Selective Electrode for Determination of Citalopram Hydrobromide in Pharmaceutical Formulation
نویسندگان
چکیده
Novel citalopram screen-printed ion selective electrodes were fabricated, characterized and used for the determination of citalopram in pharmaceutical formulations. The proposed sensors incorporated potassium tetrakis(p-chlorophenyl) borate (KTpClPB) ionophore (electrode V) and citalopram-phosphotungstate (CP-PT) ion pair complex (electrode X) as electroactive materials in screen-printed electrodes and tricresylphosphate (TCP) as solvent mediator. The fabricated electrodes demonstrated near Nernstain response over wide linear range of 4.9 × 10–1.0 × 10 M and 1.0 × 10–1.0 × 10 M citalopram with lower limit of detection of 4.9 × 10 M and 1.0 × 10 M and slope of (60.47 ± 0.80) mV decade and (59.93 ± 1.45) mV decade for electrode (V) and (X), respectively. The results showed that the proposed sensors had the characteristics such as fast and stable response, good reproducibility, long term stability (5 and 4 months) and applicability over a wide pH range of 2–9 and 2–8 for electrodes (V) and (X). The sensors displayed good selectivity for citalopram with respect to number of common foreign inorganic, organic species, excipients and the fillers added to the pharmaceutical preparation. The sensors were successfully applied for the determination of citalopram in tablet, urine and serum.
منابع مشابه
Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples
This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...
متن کاملDevelopment of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples
This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...
متن کاملA New Sensor Based on Graphite Screen Printed Electrode Modified With Cu-Nanocomplex for Determination of Paracetamol
Paracetamol is a non-steroidal anti-inflammatory drug used as an antipyretic agent for the alternative to aspirin. Conversely, the overdoses of paracetamol can cause hepatic toxicity and kidney damage. Hence, the determination of paracetamol receives much more attention in biological samples and also in pharmaceutical formulations. Here, we report a rapid<span id="transmark" style="display: non...
متن کاملIon Selective Carbon Paste Electrode For The Determination Of Flavoxate Muscle Relaxant Drug In Pharmaceutical Formulation
Abstract The utility of carbon paste electrode for the determination of flavoxate HCl modified with flavoxate-tetraphenylborate (FLX-TPB) and flavoxate-phosphotungestic acid (FLX-PTA) ion-pairs in batch mode is demonstrated. The electrodes revealed a Nernstian response over a wide concentration ranges 1.39×10-5-1x10-2 mol L-1 and1×10-5-1x10-2 mol L-1 using FLX-TPB and FLX-PTA, respectively. The...
متن کاملVoltammetric determination of acetaminophen and tryptophan using a graphite screen printed electrode modified with functionalized graphene oxide nanosheets within a Fe3O4@SiO2 nanocomposite
A high sensitive electrochemical nanostructure sensor based on graphene oxide/Fe3O4@SiO2 nanocomposite modified graphite screen printed electrode (GO/Fe3O4@SiO2/SPE) has been developed for trace analysis of acetaminophen. The electrochemical study of the modified electrode, as well as its efficiency for simultaneous voltammetric oxidation of acetaminophen and tryptophan is described. Compared w...
متن کامل