Appropriateness of sling immobilization to prevent lead displacement after pacemaker/implantable cardioverter-defibrillator implantation.

نویسندگان

  • Aster Naffe
  • Mini Iype
  • Mini Easo
  • Sandra Dejong McLeroy
  • Kelli Pinaga
  • Nancy Vish
  • Kevin Wheelan
  • Jay Franklin
  • Jenny Adams
چکیده

After pacemaker/implantable cardioverter-defibrillator (pacemaker/ICD) implantation, patients are often required to immobilize the affected arm with a sling to minimize the risk of lead displacement. We examined whether performing a resistive range-of-motion exercise protocol after pacemaker/ICD surgery would result in lead displacement and, therefore, whether sling immobilization and activity restrictions are justified. Ten subjects who had undergone pacemaker/ICD surgery performed four individual resistive range-of-motion exercises (three sets of 10 repetitions for each: one warm-up set without weight and two sets with a 1- or 2-pound hand weight) with the affected arm prior to hospital discharge. For each subject, an electrophysiology nurse specialist used a noninvasive device programmer to evaluate surgical lead placement before and after the exercises. As an adjunct to the study, we queried clinicians at 48 US hospitals about sling immobilization and activity restrictions after pacemaker/ICD implantation at their institutions. No lead displacement occurred after the weightlifting exercises were performed. Based on these results in a small group of patients, it appears that requiring the use of a joint immobilization sling is overly restrictive, promotes fear, and hinders recovery. We encourage the development of consistent discharge instructions that will promote early mobility and a safe and rapid return to normal activities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pacemaker lead endocarditis with hiccups (Kalayci)

Background: Lead-related infections that might develop after pacemaker implantation associated with high mortality and morbidity rates are challenging to manage and pose high-cost. Patients with lead-related infections usually present with fever, chills and fatigue and the treatment can be challenging unless the implant system is extracted. Case presentation: A 66-year old male patient who und...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

A Rare Cause of Cardiac Tamponade: Left Ventricular Pacemaker Malposition

The malpositioning of a pacemaker lead is an uncommon and under-reported complication of pacemaker/Automated Implantable Cardioverter-Defibrillator (AICD) placement. It can be associated with complications such as pericardial effusions and tamponade. We describe a case of an elderly woman who developed cardiac tamponade after inadvertent placement of a permanent pacing lead in the left ventricl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings

دوره 22 1  شماره 

صفحات  -

تاریخ انتشار 2009