An evaluation of the Beckman Astra 8 analyser
نویسندگان
چکیده
Introduction The Astra-8 is a floor-standing seven-channel, automatic, discrete analyser for use in the clinical chemistry laboratory. A:t present it will analyse serum for urea, sodium, potassium, chloride, total carbon dioxide, glucose, and creatinine. It calculates the anion gap and osmolality, and also the ratio of blood urea.nitrogen to creatinine when these are expressed as mg/dl. Urine may be analysed for sodium, potassium, chloride, glucose and creatinine. Provision is made for the addition of two further analytical modules when these become available. The sample tray holds up to 38 specimens and two calibrating solutions, and requests for up to 76 specimens may be entered into the machine at one time. Any combination of available tests may be requested for each specimen or group of specimens, but sodium and. potassium are always measured together. The machine may be instructed to analyse an emergency specimen at any time, after which it will return to the original sequence of specimens. The analyser is controlled by a computer to which the operator communicates by means of a keyboard and a visual-display unit (VDU). The operator can select individual tests for each specimen, enter identification numbers, enter or alter reference ranges, initiate priming of reaction vessels and automatic calibration on all or any channels, request duplicate assays, and to return to a control specimen at any desired frequency. Special procedures for routine maintenance or diagnosis of faults can be initiated frorn the keyboard. In addition the computer monitors the functioning of the instrument, detects the presence of a sample in the cup, converts the outputs from the analytical modules to analytical results, expressed either as mass (eg mg/dl) or molar (eg mmol/1) concentrations. Results are displayed on the VDU and printed on a high-speed thermal printer in a form which could be used as the report. This includes the date and time of the analysis, patient identification number, the analytical results, the reference ranges, and an indication if the result is outside that range. The analyser may also be connected to external data-processing equipment via a multipin socket. Reagents provided by the manufacturer are stored on top of the machine. They are pumped to the reaction Vessels by peristaltic pumps via preheating elements, and excess is removed via an overflow. Although the principle components of each reagent are listed on the bottle, insufficient detail is given to enable the user to prepare them. Sodium’ and potassium are measured by means of ionselective elects:odes (lithium aluminium silicate glass and valinomycin respectively). The reference electrode is a second sodium electrode in contact with a sodium solution of constant concentration. The electrodes are equilibrated prior to measurement, and 50/1 of serum or urine are required. Chloride is measured by coulometric titration with silver ions released from a silver anode. It requires 8pl of serum or 6/.tl of urine. Glucose is estimated by measuring the rate of consumption of oxygen in the presence of glucose oxidase by means of an oxygen electrode. It requires 10gl of serum or urine.
منابع مشابه
Laboratory evaluation of the Greiner G450 discrete analyser
A report of an evaluation of the Greiner G450 selective multichannel analyser is presented. Thirty different single-reagent tests can be carried out in one run at a rate between 200 and 400 tests/h. A double beam photometer allows kinetic and end-point measurements. A Radiometer FLM3 flame photometer has been included for the determination of electrolytes. The G450 analyser demonstrated excelle...
متن کاملThe use of Fuller's earth to reduce acetoacetate interference in the measurement of serum creatinine by the Beckman Astra-4 analyser
Several authors have recently re-emphasized the positive interference of acetoacetate in the measurement of creatinine using the Jaff6 reaction [1-3]. On theoretical grounds, the measurement of creatinine in the presence of acetoacetate should be possible using a kinetic method [4]. In practice, however, measurements by some instruments employing a kinetic Jaff6 method suffer from marked interf...
متن کاملEvaluation of a new multichannel analyzer, "Astra-8".
We evaluated a new multiple-channel chemistry analyzer, the Beckman "Astra-8," which is controlled by a microprocessor with 52K bytes of memory. The instrument we tested performed the following tests: Na, K, CO2, chloride, urea nitrogen, glucose, and creatinine. We compared the Astra-8 to a continuous-flow (SMA 6/60) and a discrete (Du Pont aca, urea nitrogen only) analyzer. The Astra-8 demonst...
متن کاملResponse of ion-selective sodium and potassium electrodes in the Beckman Astra 4 and Astra 8 analyzers.
We tested the response of ion-selective sodium and potassium electrodes that are a part of the new multi-channel chemical analyzers, Astra 8 and Astra 4 (Beckman). For this we used plain and albumin-containing aqueous solutions of known Na+ and K+ concentrations, varied inversely so we could assess how the concentration of each electrolyte would affect the response of the other electrode. The s...
متن کاملMeasurement of urinary constituents with the Astra-8 Multichannel Analyzer.
The Beckman Astra-8 is a computerized, discrete-microsample, multiple-test clinical chemistry analyzer. We have examined its capability to measure urine Na+, K+, Cl-, urea nitrogen, glucose, and creatinine and found that (a) the Astra measurements are linear, accurate, and precise in concentration ranges of urine analytes; (b) urine analyte concentrations measured with the Astra correlate well ...
متن کاملNotes for Contributors
had been unused for some time within the calibration period could give erroneously low results. This was most likely to happen if a series of urine samples were analysed followed by a serum, but the .effect was by no means reproducible. The manufacturer is aware of this problem, which is probably caused by deterioration of the reagent in the measuring cup, and is taking steps to correct it. Cre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of Automatic Chemistry
دوره 2 شماره
صفحات -
تاریخ انتشار 1980