Implementation of Continuous Capnography Is Associated With a Decreased Utilization of Blood Gases
نویسندگان
چکیده
BACKGROUND Capnography provides a continuous, non-invasive monitoring of the CO2 to assess adequacy of ventilation and provide added safety features in mechanically ventilated patients by allowing for quick identification of unplanned extubation. These monitors may allow for decreased utilization of blood gases. The objective was to determine if implementation of continuous capnography monitoring decreases the utilization of blood gases resulting in decreased charges. METHODS This is a retrospective review of a quality improvement project that compares the utilization of blood gases before and after the implementation of standard continuous capnography. The time period of April 2010 to September 2010 was compared to April 2011 to September 2011. Parameters collected included total number of blood gases analyzed, cost of blood gas analysis, ventilator and patient days. RESULTS The total number of blood gases after the institution of end tidal CO2 monitoring decreased from 12,937 in 2009 and 13,171 in 2010 to 8,070 in 2011. The average number of blood gases per encounter decreased from 20.8 in 2009 and 21.6 in 2010 to 13.8 post intervention. The blood gases per ventilator day decreased from 4.94 in 2009 and 4.76 in 2010 to 3.30 post intervention. The total charge savings over a 6-month period was $880,496. CONCLUSIONS Continuous capnography resulted in a significant savings over a 6-month period by decreasing the utilization of blood gas measurements.
منابع مشابه
Ventilation monitoring during monitored anesthesia care: a review.
The use of capnography during general anesthesia has become not only state of the art but also a recommended standard of care. In intubated patients, measurements of partial pressure of carbon dioxide in exhaled pulmonary gases approximate partial pressure of carbon dioxide in arterial blood under stable conditions. End-tidal carbon dioxide measurement has allowed anesthetists to continuously f...
متن کاملThe effect of maximum surgical blood ordering on blood utilization in elective surgeries in 23 hospitals of Shiraz, Iran
Abstract Background and Objectives Over ordering of blood in elective surgical procedures due to fear of bleeding and unavailability of sufficient blood can cause blood wastage and increase blood bank expenses. This study compared blood ordering and utilization after the introduction of maximum surgical blood ordering (MSBOS) in elective surgeries. Materials and Methods This cross sectiona...
متن کاملMembrane oxygenator exhaust capnography for continuously estimating arterial carbon dioxide tension during cardiopulmonary bypass.
Typically, the standard practice for measuring the arterial blood carbon dioxide tension (PaCO2) during cardiopulmonary bypass (CPB) is to take intermittent blood samples for analysis by a bench blood gas analyzer. Continuous inline blood gas monitors are available but are expensive. A potential solution is the capnograph, which was evaluated by determining how accurately the carbon dioxide ten...
متن کاملA study of mixing conditions during nitric oxide administration using simultaneous fast response chemiluminescence and capnography.
We have evaluated the mixing properties of nitric oxide in inspired gases for five different administration techniques. Nitric oxide and carbon dioxide were delivered to the ventilator system before the ventilator or after the ventilator as a continuous flow, either directly into the inspiratory limb or into a mixing chamber positioned in the inspiratory limb. Both gases were delivered as above...
متن کاملBlood gases and metabolite content and ruminal fermentation in response to diets with different fermentability in Holstein dairy cows
The objective of this study was to determine the effects of diets having different fermentability on blood gases, blood metabolites and ruminal fermentation parameters in Holstein dairy cows. Four multiparous Holstein dairy cows (665 ± 25 kg BW, 170 ± 7.0 DIM and 15±1.5 kg of milk yield), fitted with rumen cannulae, were used in a 4×4 Latin Square design with 28-d periods. Corn starch and sucro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -
تاریخ انتشار 2015