Glucose oxidase method for continuous automated blood glucose determination.

نویسندگان

  • J W Rosevear
  • K J Pfaff
  • F J Service
  • G D Molnar
  • E Ackerman
چکیده

A glucoseoxidase-peroxidasemethod for continuous automated monitoring of blood glucosehas been developed.The responseis linear over the range 0-800 mg/100 ml. Sensitivity can be maintained for 24 hr or longer and can be restored by rinsing the analytic system with sulfuric acid to permit studies of longer than 48 hr in duration. A precisionof ± 1% can be maintained between rinsesfor samplescontaining 100600 mg of glucoseper 100 ml. This method is satisfactorily specific for glucose: The response with other sugars is less than 1% of the response obtained with the same concentration of glucose. Ascorbic acid causes no significant inhibition of the response to glucose. The inhibition by uric acid has been reduced fifty-fold compared to that in other methods. Transit through the sampling catheter and analytic system requires 15 mm. Timed from the first detectable response to a change in concentration, 25% of total responseis achieved in 30 sec and 90% in 80 sec. Fifty percent of an oscillation with a half-period of 45 sec can be detected; no oscillations this short were observedin records of human blood glucose. Applicability and feasibility of this method have been demonstrated in over 2000 hr of repeated blood glucose recordingsin 12 diabetic and 6 normal subjects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Simple Image Analysis Method for Determination of Glucose by using Glucose Oxidase CdTe/TGA Quantum Dots

Glucose, as the major energy source in cellular metabolism, plays an important role in the natural growth of cells. Herein, a simple, rapid and low-cost method for the glucose determination by utilizing glucose oxidase and CdTe/thioglycolic acid (TGA) quantum dots (QDs) on a thin layer chromatography (TLC) plate has been described. The detection was based on the combination of the glucose enzym...

متن کامل

Evaluation of an automated glucose-oxidase procedure.

We evaluated a slight modification of the automated oxidase/peroxidase method for glucose determination in blood with use of 4-aminophenazone [J. Clin. Pathol. 22, 246 (1969)]. Nonsugar reducing substances did not interfere, except for ascorbic acid in very high concentrations. Lipemic sera gave slightly lower values. Values for reproducibility, specificity, and sensitivity were closer to such ...

متن کامل

An automated, saccharogenic method for determining serum amylase activity.

An automated adaptation of the Somogyl saccharogenic determination of serum amylase is described in which conventional AutoAnalyzer modules are used. Adequate sensitivity with short incubation is achieved by incorporating glucose oxidase and catalase in the substrate to destroy serum glucose during incubation. Maltose and other dialyzable oligosaccharides are measured with the alkaline copper-n...

متن کامل

Direct Automated Determination of Glucose by a Glucose Oxidase-peroxidase System.

THE DETERMINATION of glucose by the glucose oxidase-peroxidase system has been simplified by Hill and Kessler (2) with the use of an automated system first described by Skeggs (1). Wincy and Marks (3) have also developed a method using o-tolidine in the automated system. These procedures require a large quantity of sample and use of a dialyzer to separate the protein before color development. T...

متن کامل

New automated method for measuring glucose by glucose oxidase.

An economical, very sensitive and precise automated method for the determination of plasma glucose by glucose oxidase is presented. At 60 determinations per hour the method required 0.05 ml. of plasma and can conveniently determine glucose levels in the range of 0 to 500 mg/100 ml. Recovery experiments gave mean yields of 99% and, for 100 specimens analysed in duplicate, the precision was 1.24 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 15 8  شماره 

صفحات  -

تاریخ انتشار 1969