Prospective randomized trial of transthoracic echocardiography versus transesophageal echocardiography for assessment and guidance of transcatheter closure of atrial septal defects in children using the Amplatzer septal occluder.
نویسندگان
چکیده
OBJECTIVES This study sought to determine whether transthoracic echocardiography (TTE) can provide safety and efficacy equivalent to transesophageal echocardiography (TEE) for assessment and guidance of transcatheter atrial septal defect (ASD) closure in pediatric patients. METHODS We performed a prospective randomized trial of ASD closure using the Amplatzer septal occluder (ASO) from March 2008 to April 2012. Inclusion criteria were isolated secundum ASD, age 2 to 18 years, and adequate TTE windows. Forty patients were enrolled and randomized to either TEE or TTE. In the TEE group, we used "stop flow" balloon sizing to determine device size. In the TTE group, we used the average ASD diameter times 1.2 (scaled). Patients were followed up to 1 year. RESULTS Patient general and hemodynamic characteristics were similar in both groups. Procedural success was 100% in both groups. The average TEE stop flow diameter was similar to the scaled TTE diameter (15.35 ± 4.62 mm vs. 16.57 ± 5.47 mm; p = 0.46). Device size (16.0 ± 4.94 mm vs. 16.37 ± 5.05 mm, p = 0.82) and ratio of device to defect size (1.0 ± 0.06 vs. 0.99 ± 0.03, p = 0.52) were also similar. Total procedure (70.6 ± 22.98 min vs. 51.1 ± 17.61 min, p = 0.005), room (126.8 ± 28.41 min vs. 95.7 ± 20.53 min, p = 0.0004), and fluoroscopy (13.6 ± 6.17 min vs. 8.9 ± 8.45 min, p = 0.007) times were all significantly shorter in the TTE group. Neither group had significant complications during the procedure nor in follow-up. Rates of shunt resolution were similar between groups. CONCLUSIONS This study suggests that in selected pediatric patients, use of TTE is as efficacious and safe as TEE for assessment and guidance of ASD occlusion using the ASO. TTE also may offer the additional safety benefit of reduced fluoroscopy exposure.
منابع مشابه
Percutaneous closure of multiple secundum atrial septal defects using 3 amplatzer atrial septal occluder devices: evaluation by live transthoracic 3-dimensional echocardiography.
A previously healthy 12-year-old boy was admitted to the hospital with acute pneumonitis. On admission, a heart murmur was detected. The transthoracic echocardiogram showed multiple secundum atrial septal defects with left-toright shunt and signs of right ventricular volume overload. He underwent right cardiac catheterization and transesophageal echocardiogram (transesophageal echocardiography)...
متن کاملTranscatheter closure of atrial septal defects with transthoracic echocardiography.
OBJECTIVES The aim of this study is to evaluate our clinical experience using an Amplatzer septal occluder for catheter closure of a secundum atrial septal defect under transthoracic echocardiography guidance without general anaesthesia. METHODS Patients eligible for transcatheter atrial septal defect closure were selected using transthoracic echocardiography. The largest defect diameter meas...
متن کاملTranscatheter closure of atrial septal defects without fluoroscopy: feasibility of a new method.
BACKGROUND In an effort to reduce x-ray exposure, we developed a technique for transcatheter closure of atrial septal defects under echocardiographic guidance without fluoroscopy. To assess the efficiency of this procedure for routine use, we compared our initial results with those for the conventional procedure. METHODS AND RESULTS Twenty-two randomly selected patients (median age 18 years; ...
متن کاملFeasibility and Safety of Transthoracic Echocardiography-Guided Transcatheter Closure of Atrial Septal Defects with Deficient Superior-Anterior Rims
Although previous studies showed that transthoracic echocardiography (TTE) can be used to guide transcatheter closure of atrial septal defect (ASD), whether TTE can be used to guide transcatheter closure of secundum ASD with a deficient superior-anterior rim is unknown and this critical issue was addressed in the present study. A total of 280 patients with secundum ASD who underwent transcathet...
متن کاملUsefulness of transesophageal echocardiography for transcatheter closure of ostium secundum atrial septum defect with the amplatzer septal occluder.
BACKGROUND Transcatheter closure of ostium secundum atrial septum defect (ASDII) using the new self-centering occluder, Amplatzer Septal Occluder (ASO), has been well developed in recent years. We describe the importance and role of transesophageal echocardiography (TEE) in the selection and closure of such defects. METHODS Thirty patients referred for transcatheter closure of ASDII by ASO we...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JACC. Cardiovascular interventions
دوره 6 9 شماره
صفحات -
تاریخ انتشار 2013