Direct Imaging of Reconstructed Iridium Surfaces in the Field Ion Microscope
نویسندگان
چکیده
Experiments are described during which both the Ir(llO)lx2 and the Ir(1OO)lxS reconstructed surfaces could be imaged in the FIM. Furthermore evidence for a possible 1x2 reconstruction of the Ir(113) surface was found. Introduction It is well khown that on many semiconductor and some metal surfaces the topmost layer of atoms can rearrange to form structures different from those of the underlying bulk net planes. These reconstructed surfaces have been studied mainly by diffraction and scattering techniques. Except for two studies /1, 2/ FIM has contributed rather little to this subject up to now. With its unique capability of imaging single surface atoms, however, it should be able to reveal valuable atomic details of the reconstruction process inaccessible to other techniques. In the following a short account of experiments will be given during which both the reconstructed Ir(llO)lx2 and the Ir(100)1x5 surfaces as well as their emergence from the respective 1x1 structures were observed in the FIM. The experiments are described in more detail elsewhere / 3 / .
منابع مشابه
Influence of Ni Deposition and Subsequent N+ Ion Implantation at Different Implantation Energies on Nano-Structure and Corrosion Behavior of 316 Stainless Steels
Nickel films of 300 nm thickness were deposited by electron beam evaporation at room temperature on 316 stainless steels. Corrosion studies of Ni coated 316 SS have been performed after N+ ion implantation at different energies of 20, 40, 60 and 80 keV. The structure and surface morphology of the films were evaluated using X-ray diffraction (XRD), atomic force microscope (AFM) an...
متن کاملSurface Science Laboratory for Studying the Surfaces of Superconducting Radio Frequency Cavities*
A Surface Science Laboratory (SSL) has been established at JLab to study surfaces relevant to superconducting radio frequency (SRF) cavities. Current operational facilities include a scanning electron microscope equipped with energy dispersive x-ray analysis, a secondary ion mass spectrometry, a metallographic optical microscope, a transmission electron microscope, a high precision and large sc...
متن کاملRoom-temperature growth of ion-induced carbon nanofibers: Effects of ion species
Graphite surfaces were bombarded with Ne, Ar and Xe ions at 450 eV–1 keV to induce the carbon nanofiber (CNF) growth at room temperature, and the dependence of size and numerical density of ion-induced CNFs on the ion species and ion energy was investigated in detail. The ion-sputtered surfaces were covered with densely distributed conical protrusions and aligned CNFs grew on the tips, except f...
متن کامل-
In this paper a method for digitally recording four quarter-reference-wave-holograms (by CCD) in a Mach-Zehnder interferometer setup, and reconstructing the object wave-front by numerical method is presented. The terms of direct transmission, auto-correlation and conjugate wave in the four wave reconstruction are cancelled out and only one original object wave is left after overlapping. Reconst...
متن کاملProbe and Object Function Reconstruction in Incoherent Scanning Transmission Electron Microscope Imaging
Using the phase-object approximation it is shown how an annular dark-field (ADF) detector in a scanning transmission electron microscope (STEM) leads to an image which can be described by an incoherent model. The point spread function is found to be simply the illuminating probe intensity. An important consequence of this is that there is no phase problem in the imaging process, which allows va...