Fixation of Chevron trochanteric osteotomy with two wire loops in isolated acetabular component revision.

نویسندگان

  • Konstantinos T Panousis
  • Stavros D Tsifetakis
  • John Orfanos
  • Philippos Giannoulis
  • John Pilichos
  • Panayiotis J Papagelopoulos
چکیده

The use of two wire loops for fixation of the trochanteric fragment after Chevron osteotomy in revision THA achieves stable fixation with minimal hardware.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trochanteric osteotomy and fixation during total hip arthroplasty.

Once used routinely, trochanteric osteotomy in total hip arthroplasty now is usually limited to difficult primary and revision cases. There are three types: the standard trochanteric osteotomy and its variations, the trochanteric slide, and the extended trochanteric osteotomy. Each has unique indications, fixation techniques, and complications. Primary total hip arthroplasty procedures requirin...

متن کامل

Isolated acetabular revision with use of the Harris-Galante Cementless Component. Study with intermediate-term follow-up.

BACKGROUND Isolated revision of an acetabular total hip component is associated with special problems related to the retention of the femoral component. We reviewed the intermediate-term results of a series of such operations with use of the Harris-Galante Porous acetabular component. METHODS We retrospectively studied the results of ninety-five isolated acetabular revisions, specifically foc...

متن کامل

An in-vitro biomechanical study of different fixation techniques for the extended trochanteric osteotomy in revision THA

BACKGROUND The wire fixation and the cable grip fixation have been developed for the extended trochanteric osteotomy (ETO) in the revision of total hip arthroplasty (THA). Many studies reported the postoperative performance of the patients, but with little quantitative biomechanical comparison of the two fixation systems. METHODS An in-vitro testing approach was designed to record the looseni...

متن کامل

Trochanteric osteotomy and advancement: a technique for abductor related hip instability.

Current indications for trochanteric osteotomy include improving exposure to the femoral intramedullary canal through correction of proximal femoral angular deformities, such as medial greater trochanteric overhang1; improving general exposure to the acetabulum and femoral canal in complex primary and revision hip total hip arthroplasty (THA)2; and facilitating exposure to the anterosuperior ac...

متن کامل

Early loosening and secondary dislocation due to a broken trochanteric osteotomy wire following a Charnley total hip arthroplasty: a case report

We report a case of interposition of a broken trochanteric wire in the hip joint. This caused early wear of the prosthesis and dislocation of the Charnley total hip arthroplasty. The patient was treated with a revision total hip arthroplasty. This rare complication should be taken into consideration when performing a trochanteric osteotomy fixation with wiring in Charnley total hip arthroplasty.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 27 12  شماره 

صفحات  -

تاریخ انتشار 2004