Time-resolved immunofluorometric assay and specimen storage conditions for measuring urinary gonadotropins.

نویسندگان

  • M Saketos
  • N Sharma
  • T Adel
  • M Raghuwanshi
  • N Santoro
چکیده

We optimized storage conditions and validated a sensitive immunofluorometric assay (IFMA) for urinary gonadotropins. Assay linearity and parallelism for luteinizing hormone (LH) and follicle-stimulating hormone (FSH) was observed to 0.04 IU/L. Urinary LH and FSH were unaffected by changes of osmolarity from 0.5 to 3.0 mOsm/kg, and from pH 4.5 to 10.5. Serum and urine measurements of the hormones correlated well over a wide range of values: for LH, R2 = 0.94, P < 0.01; for FSH, R2 = 0.71, P < 0.01 (n = 304). Preservation of urine with glycerol (70 mL/L) and storage at -20 degrees C yielded > 80% recovery of LH and FSH after 51 weeks; this was comparable with recovery for acetone extracts of urine. Untreated urine showed loss of activity by 4 weeks of storage. Preserving urine specimens with glycerol is a simple method of storage for longitudinal study and compares favorably with acetone extraction. IFMAs can measure urinary gonadotropins reproducibly over a wide range of pH and osmotic conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-site time-resolved immunofluorometric assay of human insulin.

We describe a two-site "sandwich"-type time-resolved immunofluorometric assay for human insulin, based on use of two monoclonal antibodies with different specificities. The first antibody is immobilized on the surface of microtiter plate strip wells, the other is labeled with Eu3+. Serum samples can be assayed with one incubation step; two incubation steps are required when plasma samples are a...

متن کامل

Secretory carbonic anhydrase isoenzyme (CA VI) in human serum.

Carbonic anhydrase VI (CA VI) is a secretory isoenzyme that, by analogy to alpha-amylase, is produced in the salivary glands and delivered into saliva. To determine whether CA VI is transferred into the circulation and is detectable in human serum, we collected blood samples from four healthy subjects at 3-h intervals throughout a 24-h period and measured concentrations of CA VI by a specific t...

متن کامل

Europium and samarium as labels in time-resolved immunofluorometric assay of follitropin.

This time-resolved immunofluorometric assay for human follitropin involves use of europium- or samarium-labeled monoclonal antibodies, with an average incorporation ratio of 3 mol of Eu3+ or Sm3+ per mole of antibody. These lanthanide ions are bound to the antibody molecules by means of the anhydride of diethylenetriaminepentaacetic acid. The solid-phase antibody is immobilized inside polystyre...

متن کامل

A time-resolved immunofluorometric assay of autoantibodies to double-stranded DNA.

A time-resolved immunofluorometric assay (TRIFMA) of autoantibodies to double-stranded DNA (dsDNA) is described. Biotinylated DNA was bound to the polystyrene solid phase coated with streptavidin. F(ab1')2 fragments from antibodies raised in rabbits to human IgG were labelled with Eu3+, and used in the assay to label the bound autoantibodies to dsDNA. The measuring range covers three decades. T...

متن کامل

Determination of fetal hemoglobin by time-resolved immunofluorometric assay.

We have developed a "sandwich"-type time-resolved immunofluorometric assay (IFMA) for fetal hemoglobin (HbF) in hemolysates from adults and newborns, amniotic fluid, and plasma, based on a polyclonal and a monoclonal antibody against human fetal hemoglobin. Microtiter wells are coated with polyclonal capture antibody, and the gamma-chain-specific monoclonal tracer antibody is labeled with a eur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 40 5  شماره 

صفحات  -

تاریخ انتشار 1994