Two Point Minimum Cost Path Approach for CTA Coronary Centerline Extraction

نویسندگان

  • C. T. Metz
  • M. Schaap
  • T. van Walsum
  • W. J. Niessen
چکیده

In this work a minimum cost path approach is adopted to extract coronary artery centerlines from CTA data. The algorithm depends on the manual definition of the start and end point of the vessel. The cost image used in the minimal cost path approach is based on a vesselness measure and a smooth window function on intensity. In the majority of the cases the method was able to extract the centerlines successfully (overlap > 90%). Accuracy of the method is around two times the voxelsize of the datasets. To conclude, minimum cost path approaches have potential for coronary artery centerline extraction, but improvements, especially regarding the accuracy of the method, still need investigations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coronary Centerline Extraction via Optimal Flow Paths and CNN Path Pruning

We present a novel method for the automated extraction of blood vessel centerlines. There are two major contributions. First, in order to avoid the shortcuts that minimal path methods are prone to we find optimal paths in a computed flow field. We solve for a steady state porous media flow inside a region of interest and trace centerlines as maximum flow paths. We explain how to estimate anisot...

متن کامل

Automatic Stenoses Detection, Quantification and Lumen Segmentation of the Coronary Arteries using a Two Point Centerline Extraction Scheme

Accurate detection and quantification of stenotic regions in coronary arteries are an essential requirement for treatment planning. We present a method that automatically detects and quantifies the stenoses in the coronary arteries from CTA images. Firstly centerlines were accurately extracted using a two point minimum cost path approach and subsequently refined to be used as an initialization ...

متن کامل

Cardiac motion-corrected iterative cone-beam CT reconstruction using a semi-automatic minimum cost path-based coronary centerline extraction

In this paper a method which combines iterative computed tomography reconstruction and coronary centerline extraction technique to obtain motion artifact-free reconstructed images of the coronary arteries are proposed and evaluated. The method relies on motion-vector fields derived from a set of coronary centerlines extracted at multiple cardiac phases within the R-R interval. Hereto, start and...

متن کامل

Robust and Accurate Coronary Artery Centerline Extraction in CTA by Combining Model-Driven and Data-Driven Approaches

Various methods have been proposed to extract coronary artery centerlines from computed tomography angiography (CTA) data. Almost all previous approaches are data-driven, which try to trace a centerline from an automatically detected or manually specified coronary ostium. No or little high level prior information is used; therefore, the centerline tracing procedure may terminate early at a seve...

متن کامل

Minimum Average-Cost Path for Real Time 3D Coronary Artery Segmentation of CT Images

In this paper, we propose a Minimum Average-cost Path (MACP) model for segmenting 3D coronary arteries by minimizing the average edge cost along path in discrete 4D graph constructed by image voxels and associated radii. Prim's Minimum Spanning Tree method is used for efficient optimization of the MACP model. The centerline and the radii of the cross sections of the coronary artery are extracte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008