Mitigation of Train-Induced Floor Vibrations in Multi-Story Buildings Using a Blocking Floor
نویسندگان
چکیده
A new method is developed for reducing train–induced floor vibrations in buildings. Vibration transmitted through building columns to the upper floors can be mitigated by considerably increasing the thickness of a lower floor, which is named the “blocking floor”. This can be a desirable and inexpensive solution for vibration mitigation. The work presented by this paper shows the ability of an impedance-based wave propagation model to capture the blocking floor behavior by comparing the analytical predictions of the velocity rations with the measured velocity ratios in the frequency domain. A 4-story scale model building was designed and constructed for measuring floor vibrations induced by excitations at the base. The effectiveness of using different blocking floors with different thicknesses in the scale model to mitigate vibrations was examined. Additionally, a sandwich floor with an integral damping layer was added to the scale model building to examine the effect of enhanced energy dissipation in the blocking floor slab.
منابع مشابه
An Impedance Model Approach to Predicting Train-Induced Vibrations in Buildings
In major cities around the world, urbanization and rising land prices have been driving an increase in real estate development adjacent to, and above in many cases, railway lines and other transportation corridors. Structure-borne sound and vibrations from traffic can be are annoying to human occupants; if high, they can also be disruptive to operation of manufacturing facilities, medical facil...
متن کاملImpedance Modeling for Prediction of Train Induced Floor Vibrations
Laboratory and manufacturing facilities are frequently located in areas that experience high-frequency (greater than 30 Hz) environmental vibration. Such vibrations are a concern for the proper functioning of sensitive laboratory devices, precision manufacturing equipment as well as human comfort. A simple method to accurately predict the magnitude of high-frequency floor vibrations would allow...
متن کاملالگوریتم ابتکاری برای حل مسئله طراحی ساختمانهای چند طبقه با اعمال محدودیتهای واقعی استفاده از آسانسور
Abstract: In the past few decades along with the developing industrial units, the use of multi floor factories has increased. On the other hand according to the service provided and being in city centers, office buildings, hospitals, universities, ministries etc. represent the most multi floor buildings. One of the most costly procedures which these factories and buildings (which are multi floo...
متن کاملEvaluation of floor vibrations induced by walking in reinforced concrete buildings
Floor vibrations induced by human walking were investigated in a reinforced concrete structure. Six experimental floor structures were built in laboratories with the same dimensions and boundary conditions. Subjective tests were performed to assess the vibration serviceability of the floor structures. First, the subjects were asked to walk across a floor and then to rate the intensity of the vi...
متن کاملInvestigation of the Progressive Collapse Potential in Steel Buildings with Composite Floor System
Abnormal loads due to natural events, implementation errors and some other issues can lead to occurrence of progressive collapse in structures. Most of the past researches consist of 2- Dimensional (2D) models of steel frames without consideration of the floor system effects, which reduces the accuracy of the modeling. While employing a 3-Dimensional (3D) model and modeling the concrete slab sy...
متن کامل