Controlled clinical comparison of BACTEC plus anaerobic/F to standard anaerobic/F as the anaerobic companion bottle to plus aerobic/F medium for culturing blood from adults.

نویسندگان

  • M L Wilson
  • S Mirrett
  • F T Meredith
  • M P Weinstein
  • V Scotto
  • L B Reller
چکیده

To determine the optimal anaerobic companion bottle to pair with BACTEC Plus Aerobic/F medium for recovery of pathogenic microorganisms from adult patients with bacteremia and fungemia, we compared Plus Anaerobic/F bottles with Standard Anaerobic/F bottles, each of which was filled with 4 to 6 ml of blood. The two bottles were paired with a Plus Aerobic/F bottle filled with 8 to 12 ml of blood. A total of 14,011 blood culture sets were obtained. Of these, 11,583 sets were received with all three bottles filled adequately and 12,257 were received with both anaerobic bottles filled adequately. Of 818 clinically important isolates detected in one or both adequately filled anaerobic bottles, significantly more staphylococci (P < 0.001), streptococci (P < 0.005), Escherichia coli isolates (P < 0.02), Klebsiella pneumoniae isolates (P < 0.005), and all microorganisms combined (P < 0.001) were detected in Plus Anaerobic/F bottles. In contrast, significantly more anaerobic gram-negative bacilli were detected in Standard Anaerobic/F bottles (P < 0.05). Of 397 unimicrobial episodes of septicemia, 354 were detected with both pairs, 30 were detected with Plus Aerobic/F-Plus Anaerobic/F pairs only, and 13 were detected with Plus Aerobic/F-Standard Anaerobic/F pairs only (P < 0.05). Significantly more episodes of bacteremia caused by members of the family Enterobacteriaceae (P < 0.05) and aerobic and facultative gram-positive bacteria (P < 0.025) were detected with Plus Anaerobic/F bottles only. In a paired-bottle analysis, 810 of 950 isolates were recovered from both pairs, 90 were recovered from Plus Aerobic/F-Plus Anaerobic/F pairs only, and 50 were recovered from Plus Aerobic/F-Standard Anaerobic/F pairs only (P < 0.001). Paired Plus Aerobic/F-Plus Anaerobic/F bottles yielded significantly more staphylococci (P < 0.001), streptococci (P < 0.05), and members of the family Enterobacteriaceae (P <0.001). We conclude that Plus Anaerobic/F bottles detect more microorganisms and episodes of bacteremia and fungemia than Standard Anaerobic/F bottles as companion bottles to Plus Aerobic/F bottles in the BACTEC 9240 blood culture system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advantage of combining resin with lytic BACTEC blood culture media.

The BACTEC 9240 (Becton Dickinson, Sparks, Md.) automated blood culture system is based on the continuous monitoring of CO2 production by means of a fluorescent sensor attached to the bottom of a culture vial. We compared two media for this system, resin-containing Plus aerobic/F and Lytic anaerobic/F. Sets of Plus aerobic/F and Lytic anaerobic/F vials inoculated with similar volumes (9 +/- 2.5...

متن کامل

Controlled clinical laboratory comparison of two supplemented aerobic and anaerobic media used in automated blood culture systems to detect bloodstream infections.

A 20-ml blood sample was collected from adult patients with suspected bloodstream infections and distributed equally into the four volume-controlled bottles of a blood culture set consisting of aerobic and anaerobic BACTEC Plus/F bottles and aerobic and anaerobic BacT/Alert FAN bottles. All bottles were incubated in their respective instruments for a standard 5-day protocol or until the instrum...

متن کامل

Controlled evaluation of Bactec Peds Plus/F and Bactec lytic/10 anaerobic/F media for isolation of Salmonella enterica serovars typhi and paratyphi A from blood.

We compared anaerobic lytic (AL) and pediatric aerobic resin-containing (Peds Plus/F) blood culture media for the isolation of Salmonella enterica serotype Typhi or Paratyphi A from children. The yields from AL and Peds Plus/F media were the same with equal volumes of blood, but recovery was faster from AL medium than Peds Plus/F medium (10.7 and 16.4 h, respectively) (P < 0.001).

متن کامل

A dedicated fungal culture medium is useful in the diagnosis of fungemia: a retrospective cross-sectional study

BACKGROUND Mortality for candidemia ranges from 15% to 35%. Current guidelines recommend inoculating blood into three aerobic and three anaerobic blood culture bottles when candidemia is suspected, without mention of a fungal blood culture bottle. OBJECTIVE To determine the value of the BACTEC Myco/F Lytic blood culture media in the diagnosis of fungemia. METHODS A two-year retrospective cr...

متن کامل

Evaluation of the HB&L System for the Microbiological Screening of Storage Medium for Organ-Cultured Corneas

Aims. To compare HB&L and BACTEC systems for detecting the microorganisms contaminating the corneal storage liquid preserved at 31°C. Methods. Human donor corneas were stored at 4°C followed by preservation at 31°C. Samples of the storage medium were inoculated in BACTEC Peds Plus/F (aerobic microorganisms), BACTEC Plus Anaerobic/F (anaerobic microorganisms), and HB&L bottles. The tests were pe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 39 3  شماره 

صفحات  -

تاریخ انتشار 2001