Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring

نویسندگان

  • Hanne Roberg-Larsen
  • Silvija Abele
  • Deniz Demir
  • Diana Dzabijeva
  • Sunniva F. Amundsen
  • Steven R. Wilson
  • Vadims Bartkevics
  • Elsa Lundanes
چکیده

A rugged and high throughput capillary column (cLC) LC-MS switching platform using large volume injection and on-line automatic filtration and filter back-flush (AFFL) solid phase extraction (SPE) for analysis of environmental water samples with minimal sample preparation is presented. Although narrow columns and on-line sample preparation are used in the platform, high ruggedness is achieved e.g., injection of 100 non-filtrated water samples did not result in a pressure rise/clogging of the SPE/capillary columns (inner diameter 300 μm). In addition, satisfactory retention time stability and chromatographic resolution were also features of the system. The potential of the platform for environmental water samples was demonstrated with various pharmaceutical products, which had detection limits (LOD) in the 0.05-12.5 ng/L range. Between-day and within-day repeatability of selected analytes were <20% RSD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid Screening Method for the Analysis of Paraquat and Diquat by LC/MSD Using Selective Ion Monitoring and Large Volume Injection Application

A rapid and sensitive method for the analysis of paraquat and diquat was developed using LC/MS, electrospray ionisation (ESI), positive ion mode, selective ion monitoring (SIM) large volume injections, and minimal sample preparation. No trace enrichment was required to obtain limits of detection (LOD) below 1 μg/L, which is well below the World Health Organisation (WHO) advisory value of 10 μg/...

متن کامل

Quantification of potential genotoxic impurity in Divalproex sodium drug substance by GC-MS method

A sensitive rapid Gas Chromatography with mass spectrometry (GC-MS) method has been developed and validated for the determination of 1-Bromopropane content in Divalproex sodium drug substance. 1-Bromopropane has been considered as a potential genotoxic impurity. The lower level of detection was achieved on fused silica capillary column coated with 100% dimethylpolysiloxane stationary phase with...

متن کامل

Rapid simultaneous determination of multiple pesticide residues in traditional Chinese medicines using programmed temperature vaporizer injection-fast gas chromatography coupled with mass spectrometry.

A fast gas chromatography coupled with mass spectrometry (GC-MS) using large volume injection with programmed temperature vaporizer in solvent vent mode (PTV-LVI-SV) was developed for the trace determination of multiple pesticide residues in traditional Chinese medicines (TCMs). Experimental conditions of PTV-LVI-SV injection were optimized by central composite design. The optimized result was ...

متن کامل

A quick and Sensitive Liquid Chromatography–tandem Mass Spectrometry (LC-MS) Method for the Determination of Enalapril and Enalaprilat in Human Plasma: Application to a Bioequivalence Study

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method for the estimation of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode was operated under the multiple-reaction monitoring mode. Sample pretreatment involved in a one-step protein precipitat...

متن کامل

Highly Sensitive CE-ESI-MS/MS for Accurate Quantitation of Drugs of Abuse in Bioanalysis Using the Agilent 6490 Triple Quadrupole LC/MS System

The combination of capillary electrophoresis and mass spectrometry (CE-MS) is particularly well suited to forensic toxicology due to its high separation efficiency, selectivity and sensitivity, short analytical time, and low solvent and sample consumption. A CE-ESI-MS/MS method was developed for the quantitation of drugs of abuse in urine samples with the highly sensitive Agilent 6490 Triple Qu...

متن کامل