Evaluation of the concomitant use of two different EIA tests for HIV screening in blood banks.

نویسندگان

  • Marcia M Otani
  • Nanci A Salles
  • Angela M E Barreto
  • Claudia C Barreto
  • Dalton F Chamone
  • Ester C Sabino
چکیده

OBJECTIVE In 1998, the Brazilian Ministry of Health made it mandatory for all blood banks in the country to screen donated blood for human immunodeficiency virus (HIV) concomitantly using two different enzyme immunoassay (EIA) tests. Concerned with the best use of available resources, our objective with this study was to evaluate the usefulness of conducting two EIA screening tests instead of just one. METHODS We analyzed data from 1999 through 2001 obtained by testing 698 191 units of donated blood using two EIA HIV screening tests concomitantly at the Pro-Blood Foundation/Blood Center of São Paulo (Fundação Pró-Sangue/Hemocentro de São Paulo), which is a major blood center in the city of São Paulo, Brazil. All samples reactive in at least one of the two EIA tests were submitted for confirmation by a Western blot (WB) test, and the persons who had donated those samples were also asked to return and provide a follow-up sample. RESULTS Out of the 698 191 blood units that were donated, 2 718 of them (0.4%) had to be discarded because they were reactive to at least one of the EIA tests. There were two WB-positive donation samples that were reactive in only one HIV EIA screening test. On their follow-up samples, both donors tested WB-negative. These cases were considered false positive results at screening. Of the 2 718 donors who were asked to return and provide a follow-up sample, 1 576 of them (58%) did so. From these 1 576 persons, we found that there were two individuals who had been reactive to only one of the two EIA screening tests and who had also been negative on the WB at screening but who were fully seroconverted on the follow-up sample. We thus estimated that, in comparison to the use of a single EIA screening test, the use of two EIA screening tests would detect only one extra sample out of 410 700 units of blood. CONCLUSIONS Our data do not support the use of two different, concomitant EIA screening tests for HIV. The great majority of HIV-positive donors have already seroconverted and will be detected using only a single EIA screening test. Only persons who are going through the process of seroconversion may be missed by using a single EIA test and detected using two EIAs for screening. To screen out these individuals and decrease the residual risk of HIV transmission from the blood donated in our center, the use of other techniques, such as nucleic acid testing (NAT) or a p24 antigen assay, would be more effective.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of HIV Indeterminate Confirmatory Tests\' Results in Blood Donors in Northeast of Iran

Background and Aims: Human Immunodeficiency virus (HIV) is spreading rapidly among the people worldwide. Infection with this virus leads to immune suppression and finally acquired immune deficiency syndrome. Early HIV detection is dependent on antibody screening against virus by Enzyme Linked Immunosorbent Assay (ELISA). Some confirmatory tests such as Western Blot and Recombinant Immunobl...

متن کامل

Comparative Performance of Electrochemiluminescence Immunoassay and EIA for HIV Screening in a Multiethnic Region of China

BACKGROUND The recent approval of 4th generation HIV tests has forced many laboratories to decide whether to shift from 3rd to these tests. There are limited published studies on the comparative evaluation of these two different assays. We compare the performance of fourth-generation electrochemiluminescence immunoassay (ChIA) and third-generation enzyme linked immunosorbent assay (EIA) for hum...

متن کامل

HIV Indeterminate Western Blot Results in Blood Donors in Northeast of Iran, 2009-2014

Background and Aims: HIV is spreading rapidly among people word wide. Infection with this virus leads to immune suppression and finally acquired immune deficiency syndrome (AIDS).Early HIV detection is depended on antibody screening against virus by Enzyme Linked Immunosorbent Assay (ELISA).Some confirmatory tests such as Western Blot and Recombinant Immunobloting Assay (RIBA), are used to ve...

متن کامل

Synthetic-peptide-based enzyme-linked immunosorbent assay for screening human serum or plasma for antibodies to human immunodeficiency virus type 1 and type 2.

A synthetic-peptide-based enzyme-linked immunosorbent assay (EIA) capable of screening for antibodies to both human immunodeficiency virus type 1 (HIV-1) and HIV-2 has been developed for use in blood banks and diagnostic laboratories. Microtiter wells are coated with two synthetic peptides, one corresponding to the highly conserved envelope region of HIV-1 and another corresponding to the conse...

متن کامل

Inm-9: Cord Blood Banks and Cord Blood Donors Selection

Cord blood is a sample of blood taken from a newborn baby's umbilical cord.Cord blood is collected because it is rich in stem cells content, such as hematopoietic cells, which can be used to treat hematopoietic and genetic disorders. Cord Blood Transplantation has been used in the treatment of over 80 diseases, including leukemia, lymphoma and anemia. Advantages of Cord Blood Treatment: • ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Revista panamericana de salud publica = Pan American journal of public health

دوره 13 2-3  شماره 

صفحات  -

تاریخ انتشار 2003