Harmonic Repetitive Controller for PWM Converter

نویسندگان

  • Zhichao Liu
  • Bin Zhang
  • Keliang Zhou
چکیده

Repetitive control (RC) scheme presents an attractive solution to achieve excellent steady-state tracking error and low total harmonic distortion (THD) for periodic signals. RC can produce extremely large gains at fundamental and each harmonic frequency of reference signal to achieve all harmonics suppression. However, a DC-AC inverter always has uneven THD distribution, e.g. THD concentrates at 4k ± 1 orders for signal-phase inverter, and 6k± 1 orders for three-phase inverter. Furthermore, a digital RC requires a integral ratio of the sampling frequency and the reference frequency, whereas the digital control system cannot always meet this requirement. For example, (e.g. 60 Hz reference signal with a 5 kHz sampling frequency, or grid-connected converter under grid frequency fluctuation, etc.). In this paper, virtual delay unit (VDU) based digital nk ± m-order harmonic RC is presented to solve the problems above. The VDU produces a different virtual RC sampling frequency from the system sampling frequency. The virtual sampling frequency for digital RC can be flexibly adjusted based on the integral ratio requirement. The advantage of VDU is that it does not vary the system sampling frequency and it is easy to be realized. Furthermore, nk ± m-order harmonic repetitive controller is selected to provide a selective harmonic compensation (SHC). Experimental results of VDU based nk±morder harmonic RC for 60 Hz single-phase DC/AC inverter with 5 kHz system sampling frequency are provided to show the effectiveness of the proposed VDU-based SHC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Parallel Structure General Repetitive Controller for General Grid- Connected PWM Converters

This paper investigates parallel structure general repetitive control (PSGRC) and its error convergence rate by using exponential function properties. PSGRC offers a general repetitive control solution for power converters to mitigate power harmonics distortions. PSGRC with appropriate settings will lead to various RCs with various error convergence rates at interested harmonic frequencies, e.g...

متن کامل

Development of Average Model for Control of a Full Bridge PWM DC-DC Converter

This paper presents a detailed small-signal and transient analysis of a full bridge PWM DC-DC converter designed for high voltage, high power applications using an average model. The derived model is implemented in a typical system and used to produce the small-signal and transient characteristics of the converter. Results obtained in the analysis of the high voltage and high power design examp...

متن کامل

Frequency Domain Based Repetitive Control of Three Phase Boost PWM Rectifier under Distorted Supply Voltage Conditions

This paper presents a digital plug-in frequency domain based repetitive control scheme for minimizing the even order harmonics at the output dc link voltage and odd order harmonics in the line currents under the distorted and unbalanced supply voltage conditions. The proposed current controller consists of a conventional PI controller and a frequency domain based plug-in repetitive controller. ...

متن کامل

Closed Loop Control of Bridgeless Cuk Converter Using Fuzzy Logic Controller for PFC Applications

This paper is based on the bridgeless single-phase Ac– Dc Power Factor Correction (PFC) converters with Fuzzy Logic Controller. High frequency isolated Cuk converters are used as a modular dc-dc converter in Discontinuous Conduction Mode (DCM) of operation of Power Factor Correction. The aim of this paper is to simplify the program complexity of the controller by reducing the number of fuzzy se...

متن کامل

Design and Simulation of a PI Controlled Soft Switched Front End Converter for Switched Reluctance Motor

This paper presents the design, and simulation of a soft switched boost converter for a switched reluctance motor with a closed loop controller. A soft switching scheme is proposed in the converter with minimum components, which reduces the switching loss and stress across the switch so that the harmonic generation is reduced in the output. The switch used in this converter switched ON at zero ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017