Facile spectrophotometric determination of cerium using malachite green –iodide system in geological and environmental samples

نویسندگان

  • Etesh K Janghel
  • Y Pervez
چکیده

A simple and highly sensitive method is proposed for determination of trace amount of cerium. New method involves bleaching of greenish colour dye-malachite green, by the action of iodine, which is released by reaction between potassium iodide and cerium (IV) in acidic medium. Beer’s law is obeyed over concentration range of 0.6 to 4.6 μg cerium (IV) in final volume of 25 ml (0.024-0.184 ppm). Molar absorptivity and Sandell’s sensitivity were found to be 1.36 x 10 l mol cm and 0.002 μg cm, respectively. New method has been successf ully applied for determination of cerium in silicate rocks, high purity rare earth oxides, soil, plant tissue and natural water samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectrophotometric determination of trace amount of malachite green from water with novel magnetic silica nanoparticles

A nano-hybrid based on polystyrene derivatives and magnetite was introduced as a new sorbent for pretreatment and determine the trace amount of malachite green from aqueous solution by spectrophotometry after preconcentration by solid phase extraction (SPE). UV–Vis spectrophotometer was used for determination of MG concentration after desorption of the dye by hydrochloric acid solution in the s...

متن کامل

A flow system for the spectrophotometric determination of lead in different types of waters using ion-exchange for pre-concentration and elimination of interferences.

A flow system for the spectrophotometric determination of lead in natural and waste waters is proposed. The determination is based on the colorimetric reaction between malachite green and iodide, followed by the formation of a ternary complex between those reagents and lead cations. The developed flow system includes a lead pre-concentration step in a column packed with a cationic resin (Chelex...

متن کامل

Spectrophotometric Simultaneous Kinetic Determination of Iodide and Iodate Using Partial Least-Squares Calibration Method in a Single Kinetic Run

A rapid, sensitive and versatile kinetic method is presented for the simultaneous spectrophotometric determination of iodide and iodate by partial least-squares regression (PLS) using original and derivate data named as absorbance and rate data. The method is based on the catalytic effect of the cited anions on the reaction rate between Ce(IV) and As(III) in 2 mol l?1 sulfuric acid medium. The ...

متن کامل

Determination of malachite green and leucomalachite green residues in rainbow trout in Sanandaj City

Background and Aim: Malachite green (MG) is an organic compound which his used as a dye in textile industry. This compound is applied incorrectly and illegally in aquiculture as an antimicrobial agent. This compound has mutagenic and carcinogenic effects. Materials and Methods: In this study we determined the concentrations of MG and leucomalachite green (LMG) in the muscle tissue of 90 rainbow...

متن کامل

New Reagents for the Spectrophotometric Determination of Ranitidine Hydrochloride

A new spectrophotometric method is proposed for the assay of ranitidine hydrochloride (RNH) in bulk drug and in its dosage forms using ceric ammonium sulphate (CAS) and two dyes, malachite (MAG) green and crystal violet (CV) as reagents. The method involves the addition of a known excess of ceric ammonium sulphate to ranitidine hydrochloride in acid medium, followed by the determination of unre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009