Pulse pressure and stroke volume variations during severe haemorrhage in ventilated dogs.

نویسندگان

  • H Berkenstadt
  • Z Friedman
  • S Preisman
  • I Keidan
  • D Livingstone
  • A Perel
چکیده

BACKGROUND Similarly to systolic pressure variation (SPV), pulse pressure variation (PPV) and stroke volume variation (SVV) derived from arterial pulse contour analysis have been shown to reflect fluid responsiveness in ventilated patients. However, unlike the SPV, both PPV and SVV have not been validated during extreme hypovolaemia. The aim of the present study was to examine whether these newly introduced variables respond to gradual hypovolaemia like the SPV by increasing gradually with each step of the haemorrhage even during extreme hypovolaemia. METHODS SPV, SVV and PPV were measured in 8 dogs following initial volume loading (10% of the estimated blood volume administered as colloid solution), 5 steps of graded haemorrhage, each consisting of 10% of the estimated blood volume, followed by retransfusion of the shed blood. RESULTS The correlations of the SVV, SPV and PPV to the stroke volume (SV) throughout the study were -0.89, -0.91 and -0.91, respectively. Correlations of the CVP and the global end-diastolic volume (GEDV) of the heart chambers to the SV were 0.79 and 0.95, respectively. The SPV correlated significantly with both the PPV and the SVV (r=0.97 and 0.93 respectively). However, the PPV increased by more than 400% at 50% haemorrhage compared with increases of 200% and 120% for the SVV and %SPV, respectively. CONCLUSION This study demonstrates that the present algorithm used for the calculation of the SVV and the formula used to calculate the PPV, perform well over a wide range of preload states including severe hypovolaemia. However, the PPV changes more than the SPV and SVV. This may be due to the changing relation of the SV to the pulse pressure when the filling of the aorta is greatly decreased.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Why do pulse pressure variations fail to predict the response to fluids in acute respiratory distress syndrome patients ventilated with low tidal volume?

Respiratory-associated variations in stroke volume and pulse pressure are frequently used to predict the response to fluid administration. However, it has been demonstrated that low tidal volume ventilation may limit their use in patients with acute respiratory distress syndrome (ARDS). In this issue, a trial investigates the value of pulse pressure variation to predict fluid responsiveness in ...

متن کامل

Passive leg raising predicts fluid responsiveness in the critically ill.

OBJECTIVE Passive leg raising (PLR) represents a "self-volume challenge" that could predict fluid response and might be useful when the respiratory variation of stroke volume cannot be used for that purpose. We hypothesized that the hemodynamic response to PLR predicts fluid responsiveness in mechanically ventilated patients. DESIGN Prospective study. SETTING Medical intensive care unit of ...

متن کامل

Stroke volume variation (SVV) and pulse pressure variation (PPV) as indicators of fluid responsiveness in sevoflurane anesthetized mechanically ventilated euvolemic dogs

Changes in stroke volume variation (SVV) and pulse pressure variation (PPV) in response to fluid infusion were experimentally evaluated during vecuronium infusion and sevoflurane anesthesia in 5 adult, mechanically ventilated, euvolemic, beagle dogs. Sequential increases in central venous pressure (CVP; 3-7[baseline], 8-12, 13-17, 18-22 and 23-27 mmHg) were produced by infusing lactated Ringer'...

متن کامل

Evaluation of several methods for computing stroke volume from central aortic pressure.

Six pulse-contour methods for estimating stroke volume from a single central aortic blood pressure were evaluated in 8 dogs and 17 patients. In the dogs, wide variations in stroke volume, measured with an electromagnetic flowmeter, were obtained by pacing the heart at various rates during a control period and during several pharmacologic interventions. Good correlations existed between measured...

متن کامل

Case scenario: respiratory variations in arterial pressure for guiding fluid management in mechanically ventilated patients.

M AINTAINING perioperative optimal cardiac preload in surgical patients is paramount for precise hemodynamic management. Hypovolemia may result in tissue hypoperfusion and worsened organ dysfunction, whereas fluid overload appears to impede oxygen delivery and compromise patient outcome. Several clinical and experimental studies have demonstrated the usefulness of dynamic indices based on heart...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 94 6  شماره 

صفحات  -

تاریخ انتشار 2005