Interlaboratory variability of bilirubin measurements.
نویسندگان
چکیده
During an 8-month study, 14 laboratories used automated analytical systems to measure total bilirubin concentrations in lyophilized bovine specimens containing 38, 169, and 253 micromol/L bilirubin (2.2, 9.9, and 14.8 mg/dL, respectively). The measured mean +/- SD (n, range) were: 39 +/- 7 micromol/L (n = 90, 31-53) [2.3 +/- 0.4 mg/dL (1.8-3.1)]; 176 +/- 29 micromol/L (n = 89, 146-222) [10.3 +/- 1.7 mg/dL (8.5-13.0)]; and 260 +/- 43 micromol/L (n = 103, 208-316) [15.2 +/- 2.5 mg/dL (12.1-18.5)]. In comparison with target values, measurements were consistently lower at 4, higher at 6, and within +/- 4% at 4 laboratories for each of the three concentrations. The measured values for each concentration remained fairly constant during the study at each laboratory. We conclude that bilirubin measurements differed significantly from the established target values at most of the participating laboratories.
منابع مشابه
Application of transcutaneous bilirubinometry for screening of neonates with significant hyperbilirubinemia in the city of Kerman
In order to screen for neonatal significant hyperbilirubinemia,a propective cross sectional study was carried out on 343 full-term neonates taken to investigator in Kerman between October 1995 and july 1996.there was a linear correlation between serum bilirubin and transcutaneous bilirubinometri (r=0.85,standard error=0.004).sensitivity and specificity of this method were 95% and 84% respective...
متن کاملCreatinine Assay Attainment of Analytical Performance Goals Following Implementation of IDMS Standardization
BACKGROUND The international initiative to standardize creatinine (Cr) assays by tracing reference materials to Isotope Dilution Mass Spectrometry (IDMS) assigned values was implemented to reduce interlaboratory variability and improve assay accuracy. OBJECTIVE The aims of this study were to examine whether IDMS standardization has improved Cr assay accuracy (bias), interlaboratory variabilit...
متن کاملInvestigation into paediatric bilirubin analyses in Australia and New Zealand.
A small regional survey of direct spectrophotometric methods and a larger Australian and New Zealand survey of paediatric bilirubin analyses are described. The overall performance of both groups was unsatisfactory with an unacceptable high interlaboratory variation. This interlaboratory variation was reduced significantly by the use of a spectrophotometric method with a common standard of methy...
متن کاملA Comparison between Transcutaneous Bilirubin (TcB) and Total Serum Bilirubin (TSB) Measurements in Term Neonates
Background: Transcutaneous bilirubinometry (TCB) is a simple method for estimating bilirubin levels in neonates. This method is noninvasive, quick, and painless. We aimed to compare serum and cutaneous bilirubin measurements in term neonates.Method: In this descriptive cross-sectional study, 200 neonates with icter with birth weights of at least 2500 grams were studied. TCB was measured using a...
متن کاملPost hoc interlaboratory comparison of single particle ICP-MS size measurements of NIST gold nanoparticle reference materials.
Single particle inductively coupled plasma-mass spectrometry (spICP-MS) is an emerging technique that enables simultaneous measurement of nanoparticle size and number quantification of metal-containing nanoparticles at realistic environmental exposure concentrations. Such measurements are needed to understand the potential environmental and human health risks of nanoparticles. Before spICP-MS c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 42 6 Pt 1 شماره
صفحات -
تاریخ انتشار 1996