PURPOSE/OBJECTIVES The complex planning and quality assurance required for spine SBRT are a barrier to implementation in time-sensitive or limited resource clinical situations. We developed and validated an automated inverse planning algorithm designed to streamline planning and allow rapid delivery of conformal single fraction spine SBRT using widely available technology. MATERIALS/METHODS The Rapid Spine (RaSp) automated script successfully generated single fraction SBRT plans for fourteen complex spinal lesions previously treated at a single high-volume institution. Automated RaSp plans were limited to 5 beams with a total of 15 segments (allowing calculation-based verification) and optimized based on RTOG 0631 objectives. Standard single fraction (16 Gy) stereotactic IMRT plans were generated for the same set of complex spinal lesions and used for comparison. A conservative 2 mm posterior isocenter shift was used to simulate minor set-up error. RESULTS Automated plans were generated in under 5 min from target definition and had a mean dose to the PTV of 1663 cGy (SD 131.5), a dose to 90 % of PTV (D90) of 1358 cGy (SD 111.0), and a maximum point dose (Dmax) to the PTV of 2055 cGy (SD 195.2) on average. IMRT plans took longer to generate but yielded more favorable dose escalation with a mean dose to the PTV of 1891 cGy (SD 117.6), D90 of 1731 cGy (SD 126.5), and Dmax of 2218 cGy (SD 195.7). A 2 mm posterior shift resulted in a 20 % (SD 10.5 %) increase in cord dose for IMRT plans and a 10 % (SD 5.3 %) increase for RaSp plans. The 2 mm perturbation caused 3 cord dose violations for the IMRT plans and 1 violation for corresponding RaSp plans. CONCLUSION The Rapid Spine plan method yields timely and dosimetrically reasonable SBRT plans which meet RTOG 0631 objectives and are suitable for rapid yet robust pretreatment quality assurance followed by expedited treatment delivery. RaSp plans reduce the tradeoff between rapid treatment and optimal dosimetry in urgent cases and limited resource situations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spine Stereotactic Body Radiotherapy: Indications, Outcomes, and Points of Caution

STUDY DESIGN A broad narrative review. OBJECTIVES The objective of this article is to provide a technical review of spine stereotactic body radiotherapy (SBRT) planning and delivery, indications for treatment, outcomes, complications, and the challenges of response assessment. The surgical approach to spinal metastases is discussed with an overview of emerging minimally invasive techniques. ...

متن کامل

Stereotactic Body Radiotherapy for Lung Lesions using Multiple Phase 3D-CT Based on the Analysis of Radiobiological Parameters

Introduction: Planning target volume (PTV) is generated from internal treatment volume (ITV) using four-dimensional computed tomography (4D-CT) for enhanced therapeutic gain in the stereotactic body radiotherapy for lung lesions (SBRT-Lung). This study aimed to propose a strategy to generate ITV on multiple-phase 3D-CT and enhance therapeutic gain in SBRT-Lung. <stron...

متن کامل

Stereotactic body radiotherapy for patients with oligometastases from colorectal cancer: risk-adapted dose prescription with a maximum dose of 83–100 Gy in five fractions

We previously reported that the local control of pulmonary metastases from colorectal cancer (CRC) following stereotactic body radiotherapy (SBRT) with moderate prescription dose was relatively worse. We investigated the treatment outcomes and toxicities of patients with oligometastases from CRC treated by SBRT using risk-adapted, very high- and convergent-dose regimens. Among patients referred...

متن کامل

A review of stereotactic body radiotherapy – is volumetric modulated arc therapy the answer?

Stereotactic body radiotherapy (SBRT) is a high precision radiotherapy technique used for the treatment of small to moderate extra-cranial tumours. Early studies utilising SBRT have shown favourable outcomes. However, major disadvantages of static field SBRT include long treatment times and toxicity complications. Volumetric modulated arc therapy (VMAT) and intensity modulated radiotherapy (IMR...

متن کامل

Safety and efficacy of stereotactic body radiotherapy as primary treatment for vertebral metastases: a multi-institutional analysis

PURPOSE To evaluate patient selection criteria, methodology, safety and clinical outcomes of stereotactic body radiotherapy (SBRT) for treatment of vertebral metastases. MATERIALS AND METHODS Eight centers from the United States (n=5), Canada (n=2) and Germany (n=1) participated in the retrospective study and analyzed 301 patients with 387 vertebral metastases. No patient had been exposed to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016