Pressure measurement: which tonometer?
نویسنده
چکیده
In the search for more accurate ways to determine intraocular pressure, the Halberg applanation tonometer may represent an alternative to the Schi0tz tonometer for routine screening pressure measurements. Although between 100 to 150 measurements are generally required to gain proficiency with the Halberg, the instrument is accurate in patients with normal corneas even with very abnormal scleral rigidity, which would make Schidtz readings inaccurate. In patients with corneal disease and irregular corneal surfaces due to edema or scarring, however, the optical applanation tonometer cannot be accurately used. In these patients, also, the Schi0tz tonometer is not only inaccurate but also may consistently read low and be grossly misleading. As validated by direct measurements with a cannula inside the eyes of patients toith irregidar corneal surfaces, the electronic applanation tonometer (MacKay-Marg tonometer) provided the first measure of the true intraocidar pressure in patients with corneal edema and corneal scarring. The Bausch and Lomb air tonometer could provide readings of generally comparable accuracy but is considerably less convenient to use in patients with irritated eyes or nystagmus or after keratoplasty. In patients with corneal disease and corneal edema, even modest elevations of intraocular pressure can contribute to edema and disease. Conversely, through neglect of this factor, the group xoiih previous ocular damage has an increased likelihood of having elevated intraocular pressures and suffering irreversible damage. An adequate standard of ophthalmologic care now seems to require some provision for the measurement of pressure in patients with corneal disease.
منابع مشابه
Two-position measurement of intraocular pressure by PT100 noncontact tonometry in comparison with Goldmann tonometry
BACKGROUND The purpose of this study was to evaluate the precision of intraocular pressure measurements obtained by PT100 noncontact tonometry in a handheld and slit lamp-mounted position in comparison with that of Goldmann applanation tonometry in healthy young adults. METHODS Sixty eyes from 60 subjects (30 men and 30 women) aged 22 ± 1 (range 20-24) years participated in this study. Tripli...
متن کامل[Comparison of dynamic contour tonometry (Pascal) with pneumotonometry and Goldmann tonometry].
PURPOSE To compare the intraocular pressure measurements as defined by the Pascal tonometer, the Goldmann tonometer and the pneumotonometer. METHODS This was an observational clinical study, which included two hundred and five randomly selected subjects recruited from the Ophthalmology Department. The intraocular pressure measurements were performed with each tonometry technique in a randomiz...
متن کاملEffect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer.
AIMS To investigate the effect of central corneal thickness and corneal curvature on intraocular pressure measurements using the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer, and to assess the agreement between the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer in intraocular pressure measurement. METHODS 479 subjects underwent int...
متن کاملComparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients.
BACKGROUND To compare the intraocular pressure readings obtained with the iCare rebound tonometer and the 7CR non-contact tonometer with those measured by Goldmann applanation tonometry in treated glaucoma patients. DESIGN A prospective, cross-sectional study was conducted in a private tertiary glaucoma clinic. PARTICIPANTS OR SAMPLES One hundred nine (54 males : 55 females) patients includ...
متن کاملIntraocular pressure measurement after penetrating keratoplasty: minified Goldmann applanation tonometer, pneumatonometer, and Tono-Pen versus manometry.
The accuracy of intraocular pressure measurement with the minified Goldmann applanation tonometer, the pneumatonometer, and the Tono-Pen tonometer were compared in post-mortem human eyes which had undergone penetrating keratoplasty. Enucleated post-mortem human eyes underwent same sized (7.75 mm) or 0.5 mm oversized (8.25 mm) autologous penetrating keratoplasty. Intraocular pressure was then se...