Effects on radiation oncology treatments involving various neuromodulation devices.
نویسندگان
چکیده
OBJECT Where no society-based or manufacturer guidance on radiation limits to neuromodulation devices is available, this research provides the groundwork for neurosurgeons and radiation oncologists who rely on the computerized treatment plan clinically for cancer patients. The focus of the article is to characterize radiation parameters of attenuation and scatter when an incident therapeutic x-ray beam is directed upon them. At the time of this writing, manufacturers of Neuromodulation products do not recommend direct exposure of the device in the beam nor provide guidance for the maximum dose for these devices. METHODS Ten neuromodulation models were chosen to represent the finite class of devices marketed by Medtronic before 2011. CT simulations permitted computer treatment modeling for dose distribution analysis as used routinely in radiation oncology for patients. Phantom case results were directly compared to actual clinical patient cases. Radiation detection measurements were then correlated to computational results. Where the x-ray beam passes through the device and is attenuated, dose reduction was identified with Varian Eclipse computer modeling for these posterior locations. RESULTS Although the computer algorithm did not identify physical processes of side-scatter and back-scatter, these phenomena were proven by radiation measurement to occur. In general, the computer results underestimated the level of change seen by measurement. CONCLUSIONS For these implantable neurostimulators, the spread in dose changes were found to be -6.2% to -12.5% by attenuation, +1.7% to +3.8% by side-scatter, and +1.1% to +3.1% by back-scatter at 6 MV. At 18 MV, these findings were observed to be -1.4% to -7.0% by attenuation, +1.8% to 5.7% by side-scatter, and 0.8% to 2.7% by back-scatter. No pattern for the behavior of these phenomena was deduced to be a direct consequence of device size.
منابع مشابه
NEWS ON THE TREATMENT OF PRIMARY HEADACHES New treatments for headache
Headache disorders are common worldwide and often disabling. Until recently, treatments were borrowed from other branches of neurology and medicine. Monoclonal antibodies targeting calcitonin gene-related peptide (CGRP) ligand and receptor, small molecule CGRP receptor antagonist gepants, serotonin1F agonists, new devices to deliver currently available drugs, and neuromodulation devices have re...
متن کاملAdverse Events Involving Radiation Oncology Medical Devices: Comprehensive Analysis of US Food and Drug Administration Data, 1991 to 2015.
PURPOSE Radiation oncology relies on rapidly evolving technology and highly complex processes. The US Food and Drug Administration collects reports of adverse events related to medical devices. We sought to characterize all events involving radiation oncology devices (RODs) from the US Food and Drug Administration's postmarket surveillance Manufacturer and User Facility Device Experience (MAUDE...
متن کاملRadio-protective role of antioxidant agents
Ionizing radiation interacts with biological systems to produce reactive oxygen species and reactive nitrogen species which attack various cellular components. Radio-protectors act as prophylactic agents to shield healthy cells and tissues from the harmful effects of radiation. Past research on synthetic radio-protectors has brought little success, primarily due to the various toxicity-related ...
متن کاملCan Melatonin Help Us in Radiation Oncology Treatments?
Nowadays, radiotherapy has become an integral part of the treatment regimen in various malignancies for curative or palliative purposes. Ionizing radiation interacts with biological systems to produce free radicals, which attack various cellular components. Radioprotectors act as prophylactic agents that are administered to shield normal cells and tissues from the harmful effects of radiation. ...
متن کاملEarly onset radiation induced sarcoma of scalp: A case report
Radiation induced sarcoma is a rare but recognized complication of radiotherapy and is associated with poor prognosis, frequently occurs 5 years after completion of treatment. We report radiation-induced sarcoma in a 42 years old male, involving the left parietooccipital scalp region following treatment of brain tumor with craniotomy and post-operative radiation with 60Co machine. Diagnosis of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of X-ray science and technology
دوره 19 4 شماره
صفحات -
تاریخ انتشار 2011