Contrast Echocardiography and Clinical Safety

ثبت نشده
چکیده

The use of contrast media provides a greater diagnostic yield for echocardiographic techniques.1 In combination with the possibility of performing myocardial perfusion studies, its use can be generalized in stress echocardiography. It therefore leads us to question the safety they afford concerning adverse reactions, an issue that has recently led to the temporary withdrawal from the market of one of these products used in echocardiography. We present the case of a 42 year old man with a history of an acute anterior myocardial infarction 4 months previously, and single vessel coronary disease (100% middle anterior descending), with a normal ejection fraction and apical akinesia. He was referred to the echocardiograph laboratory for measurement of apical myocardial viability by means of stress echocardiography with dobutamine, prior to attempting revascularization. When the patient was clinically and hemodynamically stable, the study was started according to the usual protocol; contrast material was not considered necessary at this point. On reaching a dobutamine infusion dose of 10 μg/kg/min, a heart rate of 105 bpm, and a blood pressure of 140/70 mm Hg, a bolus dose of 1.5 mL of Sonovue® was given, maintaining a mechanical index of 0.3. The patient immediately developed sudden sweating, rubefaction and bradycardia, followed by severe hypotension and cardiorespiratory arrest. Advanced cardiopulmonary Letters to Editor

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diffuse Pulmonary Arteriovenous Malformation in Children: Essential Value of Contrast Echocardiography in Diagnosis

Pulmonary arteriovenous malformations (PAVM) are abnormal communications between pulmonary arteries and pulmonary veins, and most commonly congenital in nature. Although rare, it is an important consideration in cyanotic patients of unknown cause. We report 3 cases with diffuse PAVM in children with different clinical manifestations and initial diagnosis was made by transthoracic contrast echoc...

متن کامل

Contrast Enhanced Echocardiography for Detection of Intrapulmonary Shunts in Liver Transplant Candidates

Background: Intrapulmonary vascular abnormalities associated with liver cirrhosis may result in intrapulmonary right-to-left shunt and hypoxemia. The aim of this study was to use contrast enhanced echocardiography to detect intrapulmonary vascular abnormalities in patients with liver cirrhosis candidates for liver transplantation. Methods: One hundred and two adult patients underwent contrast e...

متن کامل

Contrast echocardiography for left ventricular opacification.

Intravenous contrast agents are clinically useful for objective assessment of left ventricular (LV) regional and global function in patients with sub-optimal echocardiography images. Recent concerns over the safety of second generation microbubble contrast agents have now been largely abated with the emergence of robust clinical data supporting its safety and clinical utility. With proper techn...

متن کامل

Localized Aortic Root Dissection Secondary to Contrast Agent Injection: Feasibility of Conservative Follow-up With Echocardiography

Introduction: Iatrogenic aortocoronary dissection (ACD) is a nightmare in interventional cardiology. Although ACD is rarely reported, the real-world prevalence is suspected of being higher due to unreported cases. The right coronary artery (RCA) ostium is involved in the majority of cases, and dissections are usually limited to the aortic sinus in half of the clinical presentat...

متن کامل

Recommendations on the safe use of ultrasound contrast agents.

Clinical applications and safety concerns Clinical users should balance the expected clinical benefit from ultrasound contrast agents against the possibility of associated bioeffects. Caution should be exercised in the use of microbubble ultrasound in tissues where damage to microvasculature could be dangerous. Some areas of concern include the brain, the eye, the fetus and the neonate. Clinica...

متن کامل

Safety of dobutamine stress real-time myocardial contrast echocardiography.

OBJECTIVES The aim of this study was to determine the safety of dobutamine stress myocardial perfusion imaging (MPI) obtained by real-time contrast echocardiography (RTCE) and intravenous ultrasound contrast in a large cohort of patients with suspected coronary artery disease (CAD). BACKGROUND Despite the increasing number of studies showing the potential clinical utility of myocardial contra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017