Characterization and correction of eddy-current artifacts in unipolar and bipolar diffusion sequences using magnetic field monitoring.

نویسندگان

  • Rachel W Chan
  • Constantin von Deuster
  • Daniel Giese
  • Christian T Stoeck
  • Jack Harmer
  • Andrew P Aitken
  • David Atkinson
  • Sebastian Kozerke
چکیده

Diffusion tensor imaging (DTI) of moving organs is gaining increasing attention but robust performance requires sequence modifications and dedicated correction methods to account for system imperfections. In this study, eddy currents in the "unipolar" Stejskal-Tanner and the velocity-compensated "bipolar" spin-echo diffusion sequences were investigated and corrected for using a magnetic field monitoring approach in combination with higher-order image reconstruction. From the field-camera measurements, increased levels of second-order eddy currents were quantified in the unipolar sequence relative to the bipolar diffusion sequence while zeroth and linear orders were found to be similar between both sequences. Second-order image reconstruction based on field-monitoring data resulted in reduced spatial misalignment artifacts and residual displacements of less than 0.43 mm and 0.29 mm (in the unipolar and bipolar sequences, respectively) after second-order eddy-current correction. Results demonstrate the need for second-order correction in unipolar encoding schemes but also show that bipolar sequences benefit from second-order reconstruction to correct for incomplete intrinsic cancellation of eddy-currents.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Crossing fibers, diffractions and nonhomogeneous magnetic field: correction of artifacts by bipolar gradient pulses.

In recent years, diffusion tensor imaging (DTI) and its variants have been used to describe fiber orientations and q-space diffusion MR was proposed as a means to obtain structural information on a micron scale. Therefore, there is an increasing need for complex phantoms with predictable microcharacteristics to challenge different indices extracted from the different diffusion MR techniques use...

متن کامل

Echo Planar Diffusion-weighted Mri of the Abdomen and Pelvis: Comparison of Free- Breathing Monopolar and Bipolar Spin-echo Sequences in Image Quality and Geometric Distortions

Introduction: Diffusion-weighted magnetic resonance imaging (DWI) exploits the random, thermally induced displacement of water molecules in biological tissue. Most DWI applications in the abdomen and pelvis employ single-shot spin-echo echo-planar imaging (ssEPI) due to its fast acquisition times and resultant robust performance against motion artifacts. Nevertheless EPI-based DWI suffers from ...

متن کامل

Inherent eddy current compensation for high-resolution DTI using bipolar diffusion gradients

Introduction: Clinical diffusion-weighted imaging (DWI) often employs a single-shot echo-planar imaging (EPI) readout to increase acquisition speed. This comes at a cost, however, since conventional DWI sequences employ a spin echo (SE) sequence with either unipolar or bipolar diffusion-sensitizing gradients on both sides of the 180º refocusing pulse. This configuration shortens the separation ...

متن کامل

An assessment of eddy current sensitivity and correction in single-shot diffusion-weighted imaging.

Artefacts caused by eddy currents are a major problem in diffusion weighted imaging. This is particularly acute in experiments in which a number of images with differing degrees of diffusion weighting and/or differently oriented diffusion-weighting gradients need to be combined. The echo-planar imaging sequence is particularly sensitive to the effects of residual eddy currents, especially due t...

متن کامل

Improved convection compensating pulsed field gradient spin-echo and stimulated-echo methods.

The need for convection compensating methods in NMR has been manifested through an increasing number of publications related to the subject over the past few years (J. Magn. Reson. 125, 372 (1997); 132, 13 (1998); 131, 126 (1998); 118, 50 (1996); 133, 379 (1998)). When performing measurements at elevated temperature, small convection currents may give rise to erroneous values of the diffusion c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance

دوره 244  شماره 

صفحات  -

تاریخ انتشار 2014