A Dipstick Sensor for Coulometric Acid-base Titrations

نویسنده

  • W. OLTHUIS
چکیده

By performing an acid-base titration by coulometric generation of OHor H+ ions at an inert electrode in close proximity to the pH-sensitive gate of an ISFET, it is possible to determine the acid or base concentration of a solution using the ISFET as an indicator device for the equivalence point in the titration curve. Typical values for the titration time are 0.1 to 10 s for acid or base concentrations ranging from 0.5 X low3 to 10 X 10M3 mol/l. By placing the counter electrode for the supplied current on the backside of a small piece of printed-circuit board on which the sensor-actuator is attached, we obtain a dipstick-like structure. Introduction In many applications, the ISFET pH-sensitive device offers a good alternative for the accurate but vulnerable pH glass electrode. The high impedance of the glass electrode and its construction are properties that make some applications difficult. For instance, in on-line monitoring of the blood pH during surgery, the small ISFET has already proven its advantage: new information becomes available for the surgeon, which cannot be obtained otherwise [ 11. Another new mode of operation comes forward by using the small, planar and fast ISFET pH-sensor together with an actuator electrode 121. By performing a coulometric acid-base titration in a submicrolitre volume in the proximity of the sensor, it is possible to determine the acid or base concentration of a solution. In solutions of well-defined composition, the pH can be calculated from this measurement. If the nature of the protolyte is unknown, this relationship is more complicated. However, for some applications, such as in the food industry, it is desirable to obtain the total acid concentration instead of the pH. *Present address: Valle University, Department of Electrical Engineering, A.A. 25360, Cali, Colombia. 0250-6874/89/$3.50 0 Elsevier Sequoia/Printed in The Netherlands

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic Behaviour of ISFET - based Sensor - Actuator Systems

Rapid acid-base titrations can be performed at the surface of a noble-metal electrode with coulometrically generated ions. An ISFET is used as an indicator electrode to detect the equivalence point in the resulting titration curve. The time needed to reach the equivalence point is typically 0.5 to 10 s for acid/base concentrations ranging from 0.5 x lop3 to 20 x lop3 mol 1 -I. A model is presen...

متن کامل

The Coulometric Titration of Acids and Bases in Dimethylsulfoxide Media

The coulometric titration of 20-200 peq of acids and bases in DMSO media is described. In the titration of bases, the electro-oxidation of hydrogen at a platinized platinum electrode is used as the source of protons. The conditions for 100 % current efficiency at this electrode are low current density to avoid passivity and regular treatment of the electrode with potassium dichromate-sulfuric a...

متن کامل

A fully automatic system for acid-base coulometric titrations

An automatic system for acid-base titrations by electrogeneration of H(+) and OH(-) ions, with potentiometric end-point detection, was developed. The system includes a PC-compatible computer for instrumental control, data acquisition and processing, which allows up to 13 samples to be analysed sequentially with no human intervention.The system performance was tested on the titration of standard...

متن کامل

Precise Coulometric Titrations of Potassium Dichromate

This paper reports results of a continuing investigation to evaluate coulometric methods of analysis and to develop highly precise and accurate analytical methods for important materials, based upon this technique. Earlier papers described the coulometric titrations of acids and bases [1] 1 and of halides [2]. The present research is concerned with a typical oxidation-reduction titration, the a...

متن کامل

THE ANODIC OXIDATION OF BASES IN THE SOLVENT no-CRESOL

Acid-base titrations can be carried out successfully in the solvent ??Icresol’. This is important for the determination of the acid or base content of some polymers for which ~cresol is a good solvent. The study of acid-base coulometry in nr-cresol was started because of the several advantages offered by coulometry: greater sensitivity, no problems with unstable titrants, and no need for standa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001