Evaluation of large-area, low-noise, arrays of SiPMs.
نویسندگان
چکیده
Institute for Instrumentation in Molecular Imaging, I3M-CSIC, Valencia, Spain In this work we present the first evaluation results of an array of 12x12 SiPMs MicroFC-30035-SMT from SensL. These sensors are basically identical to those custom fabricated for the brain PET insert of the MindView project, except for the larger package. Both the C-Series and MindView parts are built with the same principle resulting on low dark noise contributions. These arrays cover an active area of approximately 5x5 cm with a pitch of 4.2 mm. We have especially evaluated the 12×12 MicroFC array with monolithic scintillators. The new results are compared to former findings with the B-Series arrays. In the tests shown here, 10 mm thick black-painted crystals are used, which exit surface dimensions matches the photosensor active area. The photosensor blocks are always run at a stable temperature in the range of 20-22°C (+/0.05°C). Typical operation bias of the arrays was 30V, inferring about 600 kHz dark counts rate for each SiPM (67 kcps/mm). A resistive readout has been designed to provide information for each row and column of the SiPMs matrix. Thus, 24 signals are being digitalized, with 250 ns integration time. 9x9 Na-22 collimated sources are used in the experiments. The sources have dimensions of 1 mm in diameter and 1 mm height, and the collimators are 1.2 mm aperture. Spatial resolution results (FWHM) along the crystal surface below 2.5 mm, including source dimensions, have been found. These values are significantly improved compared to 3.5mm obtained with the B-Series in the past. At a distance of 20mm off-center, the system shows a negligible edge effect. These tests also showed a good energy resolution in the range of 16-17%.
منابع مشابه
Performance evaluation of two SiPMs arrays coupled to pixelated scintillations for PET/MR applications
Technological Educational Institute of Athens, Athens, Greece The purpose of this study is to investigate the behavior of the new generation of SensL SiPM arrays, ArrayB and ArrayM, for PET/MR applications. The evaluation of the SiPMs performance underwent with pixelated GaGG and BGO scintillators with 2×2×5 mm pixel size and various coupling schemes for 511keV and 662keV energies. To acquire r...
متن کاملMulti-electrode arrays technology for the non-invasive recording of neural signals: a review article
The recording of electrophysiological activities of brain neurons in the last half-century has been considered as one of the effective tools for the development of neuroscience. One of the techniques for recording the activity of nerve cells is the multi-electrode arrays (MEAs). Microelectrode arrays (MEAs) are usually employed to record electrical signals from electrogenic cells like neurons o...
متن کاملAll-Digital Biomedical Imaging
The appearance of miniaturized single-photon detectors has enabled massively parallel conversion of photons to digital signals that can be readily processed and/or transported with negligible losses. As a consequence, a new class of imaging sensors is emerging, known collectively as all-digital image sensors, for detection and processing of ultra-fast and complex photonic events, often present ...
متن کاملProgress report on the MindView brain PET detector module based on large area SiPMs arrays
Institute for Instrumentation in Molecular Imaging, CSIC-UPV, Valencia, Spain The main technical goal of the MindView project and, thus, the subject of this contribution, is achieving simultaneous PET/MR imaging, dedicated to brain examination in clinical research settings to study psychiatric disorders. The system will allow visualization of the relevant structures in the brain with very high ...
متن کاملCryogenic Characterization of the FBK NUV-HD SiPMs
We report on the characterization of the NUV-HD SiPMs developed at FBK at cryogenic temperature. A dedicated setup was built to measure the primary dark noise and correlated noises of the SiPMs between 40 and 300 K. Moreover a specific analysis program in conjunction with an ad-hoc data acquisition system were developed to allow the precise characterization of these parameters, some of which ca...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- EJNMMI physics
دوره 2 Suppl 1 شماره
صفحات -
تاریخ انتشار 2015