Measurement of formaldehyde concentrations in a subatmospheric steam-formaldehyde autoclave.

نویسندگان

  • D Marcos
  • D Wiseman
چکیده

A method has been developed for measuring formaldehyde concentrations in a subatmospheric steam-formaldehyde autoclave. Data obtained using this method indicate that the concentration of formaldehyde in the chamber atmosphere is not homogeneous and that it decreases rapidly with time. The penetration of formaldehyde vapour into narrow tubes has also been investigated and was shown to be dependent on the length-to-bore ratio of the tubes. The formaldehyde concentration within the tubes could be increased by using a lower vacuum in the air removal stage at the beginning of the cycle.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Processing urinary endoscopes in a low-temperature steam and formaldehyde autoclave.

Methods of disinfection and sterilisation of urinary endoscopes are considered. A small mobile low-temperature steam and formaldehyde autoclave (Miniclave 80) is evaluated and shown to be satisfactory for this purpose as judged by a variety of relevant microbiological test pieces.

متن کامل

Disinfection of heat-sensitive material by low-temperature steam and formaldehyde.

Steam under subatmospheric pressure at temperatures below 90 degrees C. rapidly killed nonsporing organisms after air had been removed by a high-vacuum pump. Most bacterial spores were killed but small proportions of the populations were very resistant. The destruction of spores was not logarithmic. The addition of formaldehyde vapour to the steam greatly increased its sterilizing power, with d...

متن کامل

Disinfection of Cystoscopes by Subatmospheric Steam and Steam and Formaldehyde at 80 ° C

The various methods of disinfection at present used for endoscopic instruments include immersion in an antiseptic solution (Miller et al., 1960), pasteurization in water (Francis, 1959), exposure to formalin vapour in a cabinet, and exposure to ethylene oxide. Though certain endoscopes are able to withstand autoclaving, this method cannot be used for all parts of the endoscope or for children's...

متن کامل

Disinfection of woollen blankets in steam at subatmospheric pressure.

Blankets may be disinfected in steam at subatmospheric pressures by temperatures below boiling point inside a suitably adapted autoclave chamber. The chamber and its contents are thoroughly evacuated of air so as to allow rapid heat penetration, and steam is admitted to a pressure of 10 in. Hg below atmospheric pressure, which corresponds to a temperature of 89 degrees C. Woollen blankets treat...

متن کامل

Gerenciamento De Custos: Aplicação Do Método De Custeio Baseado Em Atividades Em Centro De Material Esterilizado Gerenciamiento De Costos: Aplicación Del Método De Costeo Basado En Actividades En Centro De Material Esterilizado

This exploratory case study was performed aiming at implementing the Activity-based Costing (ABC) method in a Sterile Processing Department (SPD) of a major teaching hospital. Data collection was performed throughout 2006. Documentary research techniques and non participant closed observation were used. The ABC implementation allowed for learning the activity-based costing of both the chemical ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 32 6  شماره 

صفحات  -

تاریخ انتشار 1979