Anterior Chamber Angle Evaluation following Phakic Posterior Chamber Collamer Lens with CentraFLOW and Its Correlation with ICL Vault and Intraocular Pressure

نویسندگان

  • Sherif A Eissa
  • Sherin H Sadek
  • Mohamed W A El-Deeb
چکیده

Purpose. To assess intraocular pressure (IOP), lens vaulting, and anterior chamber (AC) angle width, following V4C implantable Collamer lens (ICL) procedure for myopic refractive error. Methods. A prospective case series that enrolled 54 eyes of 27 patients that were evaluated before and after V4C phakic posterior chamber Collamer lens implantation for correction of myopic refractive error. Preoperative measurement of IOP was done using Goldmann applanation tonometer and anterior chamber angle width using both Van Herick slit lamp grading system and Scheimpflug tomography imaging (Oculus Pentacam). Follow-up of the aforementioned variables was at 1, 6, and 18 months postoperatively, together with ICL vault measurements. Results. The mean baseline IOP of 11.69 ± 2.15 showed a statistically significant (P = 0.002) increase after 1 month that remained unchanged at 6 and 18 months postoperatively, with mean value of 16.07 ± 4.12, 16.07 ± 4.10, and 16.07 ± 4.13, respectively. Pentacam AC angle width showed a statistically significant decrease at 1 (P = 0.025), 6 (P = 0.016), and 18 (P = 0.010) months postoperatively, with mean preoperative value of 40.14 ± 5.49 that decreased to 25.28 ± 5.33, 25.46 ± 5.44, and 25.49 ± 5.38, at 1, 6, and 18 months, respectively. Mean ICL vault showed moderate correlation with Pentacam AC angle width at 1 (r = -0.435) and 6 (r = -0.424) months. Conclusion. V4C ICL implantation resulted in decrease in AC angle width and increase in IOP, within acceptable physiological values at all time points.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c)

BACKGROUND To objectively compare the early changes in vault over time following implantation of an Implantable Collamer Lens without (ICL V4) and with (ICL V4c) a central hole and the respective factors affecting vault change in moderate to high myopia. METHODS This prospective study comprised of 38 eyes of 38 patients implanted with ICL V4 and 39 eyes of 39 patients implanted with ICL V4c i...

متن کامل

Etiology and Management of Raised Intraocular Pressure following Posterior Chamber Phakic Intraocular Lens Implantation in Myopic Eyes

AIM To evaluate the etiology and management of elevated intraocular pressure (IOP) following posterior chamber phakic implantable collamer lens (ICL) surgery. METHODS Between 2009 and 2015, 638 eyes of 359 subjects with refractive myopia, underwent V4b and V4c (CentraFLOW) model ICL implantation. Ocular hypertension (OHT) was defined as IOP of ≥ 22 mm Hg on two separate occasions and elevated...

متن کامل

Evaluation of Phakic Posterior Chamber Intraocular Implantable Contact Lens for High Myopia

Purpose: To evaluate efficacy, predictability and safety of the surgical correction of high myopia using the phakic posterior chamber implantable collamer lens. Design: A prospective, nonrandomized, non-comparative interventional case series. Participants: Twenty seven eyes of fifteen patients aged from 20 to 46 years having high myopia were included. Intervention: STAAR modified collamer impla...

متن کامل

Posterior Chamber Toric Implantable Collamer Lenses – Literature Review

Posterior Chamber Phakic Toric Implantable Collamer Lenses have become increasingly used to correct refractive error associated with astigmatism. These devices are claimed to provide high efficacy in terms of refractive correction. This book chapter is an updated review on the safety and effectiveness and potential complications of the toric implantable collamer lens (Toric ICL) published in pe...

متن کامل

Posterior chamber phakic intraocular lens for hyperopia of +4 to +11 diopters.

PURPOSE To examine the efficacy, predictability, stability, and safety of posterior chamber phakic intraocular lens (IOL) implantation in eyes with high hyperopia. METHODS We analyzed the results of 24 eyes that received a posterior chamber hydrogel-collagen plate phakic IOL (Staar Collamer Implantable Contact Lens, ICL) for the correction of hyperopia with the goal of emmetropia. Mean follow...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016