Study on corollary of seismic base isolation system on buildings with soft storey
نویسندگان
چکیده
Soft storey buildings are characterized by having a storey which has a lot of open spaces. This soft storey creates a major weak point in an earthquake. Since soft stories are classically associated with retail spaces and parking garages, they are often on the lower stories of a building, which means that when they collapse, they can take the whole building down with them, causing serious structural damage which may render the structure totally unusable. In this study, efforts have been given to examine the effect of incorporation of isolator on the seismic behavior of buildings subjected to the appropriate earthquake for medium risk seismicity region. It duly ensures incorporating isolator with all relevant properties as per respective isolators along with its time period and damping ratio. Effort has also been made here to build up a relationship for increasing storey height and the changes for incorporating isolator with same time period and damping ratio for both lead rubber bearing (LRB) and high damping rubber bearing (HDRB). Dynamic analyses have been carried out using response spectrum and time history analysis. Behavioral changes of structural parameters are investigated. The study reveals that the values of structural parameters reduce a large amount while using isolator. However, LRB is found beneficial than HDRB. The structure experiences huge storey drift at the soft storey level that may be severe and cause immature failure. The amount of masonry infill is very vital for soft storey buildings as its decrement increases reasonable displacements.
منابع مشابه
Assessment of Structure-Specific Fragility Curves for Soft Storey Buildings Implementing IDA and SPO Approaches
Soft storey building is popular due to the functional and aesthetic purpose, despite its weakness in resisting seismic excitation. Nonlinear Static (Pushover) Analysis (POA) is a time saving and simple assessment procedure prosposed in Eurocode 8 (EC8). However, its reliability in designing structure still remains a question. At the first stage, seismic performance of several building models us...
متن کاملInfluence of Seismic Pounding on RC Buildings with and without Base Isolation System Subject to Near-Fault Ground Motions
Building pounding occurs between two adjacent buildings with small gap or without sufficient separation distance. It leads to damage buildings during earthquake due to impact. Many researchers have investigated building pounding based on impact force reduction and energy dissipation increase, when two buildings collide with each other. In numerical investigations, using specific link element, i...
متن کاملEvaluation of Seismic Vulnerability of Reinforced Concrete Buildings Adjacent to the Deep Excavations
In this study, the effect of deep excavation on the seismic response of RC moment resisting building systems has been studied. Deep excavation can cause significant changes in the stress and strain levels of soil environment and also changes in the propagation of seismic waves. This leads to permanent displacements in the foundation system. In this study, three RC building systems, i.e. 5, 10, ...
متن کاملSimplified design guidelines for seismic base isolation in multi-storey buildings for Bangladesh National Building Code (BNBC)
Seismic base isolation is now a days moving towards a very efficient tool in seismic design of structure. Increasing flexibility of structure is well achieved by the insertion of these additional elements between upper structure and foundation as they absorb larger part of seismic energy. However in Bangladesh, this research is still young for building structures. Therefore, this is a burning q...
متن کاملOPTIMUM DESIGN OF TMD SYSTEM FOR TALL BUILDINGS
High tall buildings are more susceptible to dynamic excitations such as wind and seismic excitations. In this paper, design procedure and some current applications of tuned mass damper (TMD) were studied. TMD was proposed to study response of 20 storey height building to seismic excitations using time history analysis with and without the TMD. The study indicates that the response of structur...