Influence of disinfection with peracetic acid and hypochlorite in dimensional alterations of casts obtained from addition silicone and polyether impressions.

نویسندگان

  • Daher Antonio Queiroz
  • Marcelo Massaroni Peçanha
  • Ana Christina Claro Neves
  • Fausto Frizzera
  • Mateus Rodrigues Tonetto
  • Laís Regiane Silva-Concílio
چکیده

Dental impressions disinfection is important to reduce the risk of cross contamination but this process may produce dimensional distortions. Peracetic acid is a disinfectant agent with several favorable characteristics yet underutilized in Dentistry. The aim of this paper is to compare the dimensional stability of casts obtained from addition silicone and polyether impressions that were immersed for 10 minutes in a solution of 0.2% peracetic acid or 1% sodium hypochlorite. Sixty samples in type IV gypsum were produced after a master cast that simulated a full crown preparation of a maxillary premolar. Samples were divided in 6 groups (n = 10) according to the impression material and disinfection agent: Group AC--addition silicone control (without disinfectant); Group APA--addition silicone + 0.2% peracetic acid; Group AH--addition silicone + 1% sodium hypochlorite; Group PC--polyether control (without disinfectant); Group PPA--polyether + 0.2% peracetic acid; Group PH--polyether + 1% sodium hypochlorite. Cast height, base and top diameter were measured and a mean value was obtained for each sample and group all data was statistically analyzed (ANOVA, p < 0.05). There was not a significant statistical difference between addition silicone and polyether impressions regardless of the disinfectant materials. It can be concluded that disinfection with the proposed agents did not produce significant alterations of the impressions and the peracetic acid could be considered a reliable material to disinfect dental molds.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Disinfection on the Surface Roughness of Dental Casts Retrieved from Addition Silicone Impressions

Background and aim: Changes in the physical properties of casts retrieved from disinfected impressions are a common problem in the fabrication of dental prostheses. However, there are limited data available about the effect of disinfecting solutions on the surface roughness of casts. This study aimed to assess the surface roughness of casts retrieved from addition silicone impressions disinfect...

متن کامل

Hardness and Surface Detail Reproduction of Gypsum Casts Retrieved from Addition Silicone Impressions Disinfected for Different Time Points

Background and Aim: Bacterial colonization occurs following contamination of impression materials with blood and saliva. However, not all disinfecting agents are compatible with the impression materials and may cause changes in the resultant casts. The purpose of this study was to assess the impact of various immersion time of addi-tion silicon impressions in different disinfecting solutions on...

متن کامل

Effect of Three Disinfectants on Dimensional Changes of Different Impression Materials

Background and Aim: Disinfection of dental impression materials can alter their dimensional stability, which in turn can affect the accuracy of dental casts. This study aimed to determine the effect of three disinfectants on the dimensional changes of ir-reversible hydrocolloid impression materials and addition silicones. Materials and Methods: Forty alginate and 40 addition silicone impressio...

متن کامل

Dimensional measurement accuracy of recent polyether and addition silicone monophase impression materials after immersion in various disinfectants : An in vitro study

Introduction: The aim of this study was to evaluate and compare the long-term dimensional measurement accuracy of recent polyether and addition silicone monophase impression materials after their immersion in three disinfectants (dual phenol, 2% glutaraldehyde and 0.5% sodium hypochlorite) for 10 minutes and 1 hour. Methodology: Two standardized stainless steel dies were prepared (ADA specifica...

متن کامل

The Effects of Disinfectants on Dimensional Accuracy and Surface Quality of Impression Materials and Gypsum Casts

BACKGROUND The study aimed to evaluating the effect of disinfecting impression materials on the dimensional accuracy and surface quality of the resulting casts. METHODS Impressions of a steel die constructed according to ANSI/ADA specification No.18 were made with each of alginate, addition cured silicone, condensation cured silicone and zinc oxide eugenol paste, and disinfected consequently ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 14 6  شماره 

صفحات  -

تاریخ انتشار 2013