Topographic measurements of eyelids and orbit in enucleated eyes with hydroxyapatite integrated implant versus PMMA implant

نویسندگان

  • S Gradinaru
  • M Totir
  • R Iancu
  • C Leasu
  • S Pricopie
  • S Yasin
  • R Ciuluvica
  • E Ungureanu
چکیده

INTRODUCTION This study reports our results relating to palpebral eyelid fissure and orbital measurements following evisceration with orbital implantation of hydroxyapatite integrated implant and PMMA implant. MATERIALS AND METHODS This study is a prospective study of 43 patients that underwent evisceration for different ocular affections at University Emergency Hospital Bucharest, Ophthalmology department between January 2009 and September 2010 (Group A comprising of twenty patients had the coralline hydroxyapatite implant -Integrated Ocular Implants, USA and Group B comprising of twenty-three received non-integrated PMMA ocular implants) .The outcomes measured were the degree of exo /enophthalmos, horizontal eyelid fissure and palpebral fissure height at 4 years after surgical intervention related to measurement to the contralateral eye. RESULTS Horizontal eyelid fissure (HEF) was suffering a shortening of 7.4% in the group B versus the contralateral eye, and only 1.9% in the group A related to the contralateral eye. Eyelid fissure height was greater in the group B with 5.2% regarding the contralateral eye, and 1.2% in group A. The degree of enophthalmia was higher in the group B of 4 mm versus the contralateral eye and lower in group A 1.5 mm regarding the contralateral eye. CONCLUSIONS . Although a hydroxyapatite implant may be not as economic as a PMMA implant, a patient must be warned about the effect on its ocular structures in time and that cosmetic appearance over years will change more dramatically than in the fellow normal eye. Therefore preoperative counseling of the patient is crucial in long term patient satisfaction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Integrated hydroxyapatite implant and non-integrated implants in enucleated Asian patients.

INTRODUCTION This study compares the outcome and complications of integrated hydroxyapatite implant and non-integrated orbital implants following enucleation in Asian patients. MATERIALS AND METHODS This is a retrospective study of enucleated patients with coralline hydroxyapatite implants versus non-integrated implants (acrylic, glass and silicone) at the Singapore National Eye Centre from J...

متن کامل

Evaluation of ocular hydroxyapatite implant with Tc-99m MDP bone scan [Persian]

Static bone scan was performed in 46 patients for evaluation of ocular Hydroxyapatite Vascularization. Study Findings indicated that bone scan, with TC-99m MDP is an appropriate method for evaluation of Hydroxyapatite Vascularization and for estimating the time For peg insertion into the Hydroxyapatite implant. Our study showed proper Hydroxyapatite Vascularization when the ratio of activ...

متن کامل

Mobility of hydroxyapatite orbital implant covered with autologous sclera.

PURPOSE To evaluate the mobility of a hydroxyapatite implant covered with autologous sclera from the enucleated globes of patients with severe atrophy of the eyeball or eyelid retraction. METHODS This implant was used in seven patients with phthisis bulbi. We measured the movement of the implant by photographic analysis of the anterior orbit and by using a strain gauge. RESULTS At 1-3 years...

متن کامل

Artificial eye amplitudes and characteristics in enucleated socket with porous polyethylene spherical and quad-motility implant.

PURPOSE To compare artificial eye amplitudes in enucleated socket with porous polyethylene either spherical or quad-motility implant and study the characteristics of artificial eyes fit with the two orbital implants. METHODS A total of 21 patients were prospectively studied who underwent enucleation because of an intraocular melanoma and the randomization defined a porous polyethylene either ...

متن کامل

Problems with the hydroxyapatite orbital implant: experience with 250 consecutive cases.

The coral derived hydroxyapatite sphere is a popular, integrated orbital implant designed to provide improved motility of the ocular prosthesis following enucleation. Although the implant has rapidly become widely used by ophthalmologists, little information is available regarding the problems of this technique in a large series of cases. Experience with 250 consecutive cases of hydroxyapatite ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2014