Detection of Abnormal Glucose Tolerance in Africans Is Improved by Combining A1C With Fasting Glucose: The Africans in America Study

نویسندگان

  • Anne E. Sumner
  • Caroline K. Thoreson
  • Michelle Y. O'Connor
  • Madia Ricks
  • Stephanie T. Chung
  • Marshall K. Tulloch-Reid
  • Jay N. Lozier
  • David B. Sacks
چکیده

OBJECTIVE Abnormal glucose tolerance is rising in sub-Saharan Africa. Hemoglobin A1c by itself and in combination with fasting plasma glucose (FPG) is used to diagnose abnormal glucose tolerance. The diagnostic ability of A1C in Africans with heterozygous variant hemoglobin, such as sickle cell trait or hemoglobin C trait, has not been rigorously evaluated. In U.S.-based Africans, we determined by hemoglobin status the sensitivities of 1) FPG ≥5.6 mmol/L, 2) A1C ≥ 5.7% (39 mmol/mol), and 3) FPG combined with A1C (FPG ≥5.6 mmol/L and/or A1C ≥5.7% [39 mmol/mol]) for the detection of abnormal glucose tolerance. RESEARCH DESIGN AND METHODS An oral glucose tolerance test (OGTT) was performed in 216 African immigrants (68% male, age 37 ± 10 years [mean ± SD], range 20-64 years). Abnormal glucose tolerance was defined as 2-h glucose ≥7.8 mmol/L. RESULTS Variant hemoglobin was identified in 21% (46 of 216). Abnormal glucose tolerance occurred in 33% (72 of 216). When determining abnormal glucose tolerance from the OGTT (2-h glucose ≥7.8 mmol/L), sensitivities of FPG for the total, normal, and variant hemoglobin groups were 32%, 32%, and 33%, respectively. Sensitivities for A1C were 53%, 54%, and 47%. For FPG and A1C combined, sensitivities were 64%, 63%, and 67%. Sensitivities for FPG and A1C and the combination did not vary by hemoglobin status (all P > 0.6). For the entire cohort, sensitivity was higher for A1C than FPG and for both tests combined than for either test alone (all P values ≤ 0.01). CONCLUSIONS No significant difference in sensitivity of A1C by variant hemoglobin status was detected. For the diagnosis of abnormal glucose tolerance in Africans, the sensitivity of A1C combined with FPG is significantly superior to either test alone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A1C Combined With Glycated Albumin Improves Detection of Prediabetes in Africans: The Africans in America Study

OBJECTIVE Slowing the diabetes epidemic in Africa requires improved detection of prediabetes. A1C, a form of glycated hemoglobin A, is recommended for diagnosing prediabetes. The glycated proteins, fructosamine and glycated albumin (GA), are hemoglobin-independent alternatives to A1C, but their efficacy in Africans is unknown. Our goals were to determine the ability of A1C, fructosamine, and GA...

متن کامل

The survey of abnormal glucose tolerance and insulin resistace and incidence of diabetes type 2 in poly cystic ovary syndrome patients in Shiraz

Background: Polycystic ovarian syndrome is one of the most commen hyper androgenic disorders affecting women, its prevalence being estimated at 5% – 10%. Our goal was to survey abnormal glucose tolerance, insulin resistance and incidence of diabetes type 2 in patients with polycystic ovary syndrome. Materials and methods: This investigation is a descriptive – analytic study which is done to su...

متن کامل

Metabolic Syndrome Does Not Detect Metabolic Risk in African Men Living in the U.S.

OBJECTIVE Metabolic risk and metabolic syndrome (MetSyn) prevalence were compared in Africans who immigrated to the U.S. and African Americans. If MetSyn were an effective predictor of cardiometabolic risk, then the group with a worse metabolic risk profile would have a higher rate of MetSyn. RESEARCH DESIGN AND METHODS Cross-sectional analyses were performed on 95 men (39 Africans, 56 Africa...

متن کامل

Noninvasive skin fluorescence spectroscopy for detection of abnormal glucose tolerance☆

The ENGINE study evaluated noninvasive skin fluorescence spectroscopy (SFS) for detection of abnormal glucose tolerance (AGT). The AGT detection performance of SFS was compared to fasting plasma glucose (FPG) and hemoglobin A1C (A1C). The study was a head-to-head comparison of SFS to FPG and A1C in an at-risk population of 507 subjects, with no prior diagnosis of diabetes, each of whom received...

متن کامل

Hemoglobin A1c Versus Oral Glucose Tolerance Test in Postpartum Diabetes Screening

OBJECTIVE To determine the usefulness of measuring hemoglobin A(1c) (A1C), alone or combined with the fasting glucose test, compared with the oral glucose tolerance test (OGTT) for the reassessment of the carbohydrate metabolism status in postpartum women with a history of gestational diabetes mellitus (GDM). RESEARCH DESIGN AND METHODS We evaluated the status of carbohydrate metabolism by pe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 38  شماره 

صفحات  -

تاریخ انتشار 2015