Robotic Ablation of Atrial Fibrillation
نویسندگان
چکیده
BACKGROUND Pulmonary vein isolation (PVI) is an established treatment for atrial fibrillation (AF). During PVI an electrical conduction block between pulmonary vein (PV) and left atrium (LA) is created. This conduction block prevents AF, which is triggered by irregular electric activity originating from the PV. However, transmural atrial lesions are required which can be challenging. Re-conduction and AF recurrence occur in 20 - 40% of the cases. Robotic catheter systems aim to improve catheter steerability. Here, a procedure with a new remote catheter system (RCS), is presented. Objective of this article is to show feasibility of robotic AF ablation with a novel system. MATERIALS AND METHODS After interatrial trans-septal puncture is performed using a long sheath and needle under fluoroscopic guidance. The needle is removed and a guide wire is placed in the left superior PV. Then an ablation catheter is positioned in the LA, using the sheath and wire as guide to the LA. LA angiography is performed over the sheath. A circular mapping catheter is positioned via the long sheath into the LA and a three-dimensional (3-D) anatomical reconstruction of the LA is performed. The handle of the ablation catheter is positioned in the robotic arm of the Amigo system and the ablation procedure begins. During the ablation procedure, the operator manipulates the ablation catheter via the robotic arm with the use of a remote control. The ablation is performed by creating point-by-point lesions around the left and right PV ostia. Contact force is measured at the catheter tip to provide feedback of catheter-tissue contact. Conduction block is confirmed by recording the PV potentials on the circular mapping catheter and by pacing maneuvers. The operator stays out of the radiationfield during ablation. CONCLUSION The novel catheter system allows ablation with high stability on low operator fluoroscopy exposure.
منابع مشابه
Effects Of Fast Pathway Ablation On The Concealment Zone And Electrophysiological Behavior Of AV-Node During Atrial Fibrillation.
Objectives: Dual pathways have a determinant role in the occurrence of atrio nodal tachyarrhythmia (AVNRT). The aim of present study is to determine the role of slow pathway (SP) in the concealment zone and protective role of AV node during atrial fibrillation (AF). Material &Methods: In 7 isolated nodal rabbit preparation zone of concealment and concealed conduction is quantified by Specif...
متن کاملEffect of Oral Anticoagulant Therapy on Coagulation Activity and Inflammatory Markers in Patients with Atrial Fibrillation Undergoing Ablation: A Randomized Comparison between Dabigatran and Warfarin
Atrial fibrillation (AF) is associated with inflammatory and hypercoagulability state. Previous studies evaluated the safety and efficacy of dabigatran and warfarin in prevention of thrombothic complications. This study was intended to assess the influence of these drugs on hemostatic and inflammatory markers among patient underwent pulmonary vein ablation. A total of 100 patients with AF w...
متن کاملEffect of Oral Anticoagulant Therapy on Coagulation Activity and Inflammatory Markers in Patients with Atrial Fibrillation Undergoing Ablation: A Randomized Comparison between Dabigatran and Warfarin
Atrial fibrillation (AF) is associated with inflammatory and hypercoagulability state. Previous studies evaluated the safety and efficacy of dabigatran and warfarin in prevention of thrombothic complications. This study was intended to assess the influence of these drugs on hemostatic and inflammatory markers among patient underwent pulmonary vein ablation. A total of 100 patients with AF w...
متن کاملIncidence and Long-Term Follow-Up of Silent Cerebral Lesions after Pulmonary Vein Isolation using a Remote Robotic Navigation System as Compared to Manual Ablation Running title: Rillig et al.; Robotic AF Ablation and Silent cerebral lesion
Background-The incidence of silent cerebral lesions (SCL) after atrial fibrillation (AF) ablation
متن کاملThe Comparison between Robotic and Manual Ablations in the Treatment of Atrial Fibrillation: A Systematic Review and Meta-Analysis
OBJECTIVE To examine in what aspects and to what extent robotic ablation is superior over manual ablation, we sought to design a meta-analysis to compare clinical outcomes between the two ablations in the treatment of atrial fibrillation. METHODS AND RESULTS A literature search was conducted of PubMed and EMBASE databases before December 1, 2013. Data were extracted independently and in dupli...
متن کاملRemote Robotic Navigation and Electroanatomical Mapping for Ablation of Atrial Fibrillation – Considerations for Navigation and Impact on Procedural Outcome Short Title: Remote Robotic Navigation for AF Ablation
Background: Radiofrequency current (RFC) ablation of atrial fibrillation (AF) requires high technical skills to achieve optimal catheter stability and is associated with an individually high X-ray exposure to both the patient and the operator. In order to facilitate catheter navigation and to reduce the operator’s X-ray burden remote navigation (RN) systems have been developed. Considerations f...
متن کامل