چکیده
The role of patent foramen ovale (PFO) in cryptogenic stroke has received increasing attention in recent times (1). Cryptogenic stroke via PFO is a form of paradoxical embolism. Formerly diagnosable during life only by cardiac catheterization (2), PFOassociated paradoxical embolism can nowadays be diagnosed noninvasively by echocardiography. Performance of a Valsalva maneuver is an integral part of the echocardiographic examination. Unfortunately, in most of the textbooks on echocardiography and published literature on the detection of PFO by echocardiography, the use of the Valsalva maneuver was either not mentioned or not specified as to which phase should be imaged. Under normal conditions, a PFO does not allow an interatrial shunt to occur from either left to right or from right to left. However, in cases of increased right atrial pressure, as in pulmonary embolism or during a Valsalva maneuver such as when straining during defecation or childbirth, a right-to-left interatrial shunt will occur through a PFO. It should be noted that it is not during the strain phase but during the release phase of the Valsalva maneuver that imaging of the interatrial septum should be performed. To illustrate this point, there is the case of a 50-year-old woman with cerebral embolism accompanying pulmonary embolism, in whom indicator dilution curves using ascorbate as an indicator and polarographic technique for detection (Fig. 1) (3) were performed. In each panel, the platinum electrode placed percutaneously in the femoral artery (FA) was the sensing side following right atrial (RA) injection of 300 mg ascorbate; recordings at a slow paper speed were made simultaneously with electrocardiographic lead II (L2) and right atrial pressure (RAp), except in the 2nd and 4th panels (Fig. 1) where connection with the strain gauge was turned off. There was apparently no evidence of a right-to-left interatrial shunt both before and during the strain phase of the Valsalva maneuver. However, following release of the Valsalva maneuver, as shown in panel 3, of Figure 1, there was a small right-to-left (R3L) interatrial shunt, which became larger, as depicted in the 4th panel, following release of a more strenuous Valsalva maneuver. Therefore, it is extremely important to continue echocardiographic imaging not only during the strain phase but also the release phase of the Valsalva maneuver so as not to miss the diagnosis of paradoxical embolism (2). Furthermore, clinicians should not just write on the request form “to rule out cardiogenic emboli” when sending a patient with cryptogenic stroke to the echocardiographic laboratory. What the echocardiographic technician or even the echocardiographer usually does is concentrate on ruling out a left atrial thrombus, a left atrial myxoma, mitral valve prolapse, vegetations on the mitral or aortic valve, a left ventricular thrombus or ventricular aneurysm, dilated cardiomyopathy, or atherosclerotic plaques in the ascending aorta. Of couse, it is also possible to detect an interatrial septal defect or an atrial septal aneurysm or a PFO, the last usually only on transesophageal echocardiography. To rule out paradoxical embolism, one needs to reverse the interatrial pressure gradient, because normally left atrial pressure is higher than right atrial and therefore no right-to-left shunt will occur, unless we artificially reverse this gradient by raising the right atrial pressure above the left atrial, such as by performance of a Valsalva maneuver. Therefore, it is very important to put on the requisition form to the echocardiographic laboratory not just “to rule out cardiogenic emboli” but also to “rule out paradoxical embolism.” For the latter it is not only necessary during echocardiography to perform a Valsalva maneuver following the intravenous injection of agitated saline or contrast medium but also to obtain images during both the strain phase and the release phase of the Valsalva maneuver (2–14). That underdiagnosis of PFO by echocardiography in patients with paradoxical embolism can result when appropriate technique is not used has been demonstrated in the past (15, 16). But it is not so much of a question of transesophageal versus transthoracic approach that is important in the echocardiographic diagnosis of paradoxical embolim as is the proper conduct of the Valsalva maneuver during the echocardiographic examination. As a matter of fact, the sedated state of the patient necessary for the trans-
منابع مشابه
A comparison of transesophageal echocardiography and transcranial Doppler sonography with contrast medium for detection of patent foramen ovale.
BACKGROUND Patent foramen ovale as a possible stroke risk factor can be diagnosed with transcranial Doppler sonography (TCD) by detecting intravenous contrast medium crossing from the right to the left atrium. The present study evaluates the reliability of this method. SUMMARY OF REPORT We performed TCD and transesophageal echocardiography simultaneously in 50 patients using galactose microbu...
متن کاملPatent foramen ovale with right to left shunt as a cause of hypoxia.
Patent foramen ovale with right to left shunt as a cause of hypoxia without Eisenmengers physiology or with only moderately pulmonary artery pressures is an uncommon presentation. Initial diagnosis via transesophageal echocardiography requires detection of a shunt with either color Doppler or agitated saline contrast with or without Valsalva maneuver. This rare but diagnosable case presented wa...
متن کاملProvoked right-to-left shunt in patent foramen ovale associates with ischemic stroke in posterior circulation.
BACKGROUND AND PURPOSE Right-to-left shunt (RLS) via the patent foramen ovale is an important cause of cryptogenic stroke. The Valsalva maneuver provokes or enhances RLS, but RLS can also occur during normal respiration. This study examined whether the ischemic lesion pattern differs depending on the character of RLS. METHODS All consecutive patients with a patent foramen ovale (diagnosed by ...
متن کاملImpending paradoxical embolism.
To the Editor: The echocardiogram on the cover of the June 1, 1999, issue of Circulation is a beautiful illustration of an impending paradoxical embolism. Unfortunately, neither the text1 nor the key words of the article made any mention of this condition. Impending paradoxical embolism2 is a surgical emergency. This diagnosis would not have been possible before the advent of echocardiography. ...
متن کاملInfluence of the Valsalva maneuver on cardiac hemodynamics and right to left shunt in patients with patent foramen ovale
The purpose of this study was to investigate the influence of the Valsalva maneuver (VM) on cardiac hemodynamics in patients with patent foramen ovale (PFO). Sixty-five patients who were highly suspected to have PFO were included. The changes in E, A, E/A ratio of mitral valve blood flow, E, A, E/A ratio of tricuspid valve blood flow, left ventricular end-diastolic volume, area and right atrial...
متن کاملIs the patent foramen ovale closure the best option?
UNLABELLED Patent foramen ovale (PFO) closure is indicated in some cases to protect patients against embolic events. The aim of this study was to certify that the method of PFO closure to prevent microemboli (MES) is reliable, using contrast enhanced transcranial Doppler (cTCD) as a diagnostic and follow-up tool. METHODS cTCD was performed before and after PFO closure in 20 patients. Results ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 45 7 شماره
صفحات -
تاریخ انتشار 2005