Electrocardiographic reference ranges derived from 79,743 ambulatory subjects.

نویسندگان

  • Jay W Mason
  • Douglas J Ramseth
  • Dennis O Chanter
  • Thomas E Moon
  • Daniel B Goodman
  • Boaz Mendzelevski
چکیده

BACKGROUND Reference ranges for electrocardiogram (ECG) intervals, heart rate, and QRS axis in general use by medical personnel and ECG readers are unrepresentative of true age- and sex-related values in large populations and are not based on modern electrocardiographic and ECG reading technology. METHODS AND RESULTS The results of ECG interpretation by cardiologists using digital technology for viewing and interpreting ECGs were compiled from single, baseline ECGs of 79,743 individuals included in pharmaceutical company-sponsored clinical trials. Women comprised 48% of the total population. Ages ranged from 3 months to 99 years, and the bulk of the population (56%) was aged 40 to 70 years. Striking differences in numerical ECG values based on age and sex were observed. A subgroup of 46,129 individuals with a very low probability of cardiovascular disease was identified. The following were the reference ranges for this subgroup, determined using the 2nd and 98th percentiles: heart rate, 48 to 98 beats/min; PR interval, 113 to 212 milliseconds; QRS interval, 69 to 109 milliseconds; frontal plane QRS axis, -40 degrees to 91 degrees ; QT interval, 325 to 452 milliseconds; QTc-Bazett, 361 to 457 milliseconds; and QTc-Fridericia, 359 to 445 milliseconds. There were marked age- and sex-related variations in the reference ranges of this subgroup, and they differ substantially from previously reported norms. Small differences were observed in ECG values obtained using our digital methods as compared with readings done using paper tracings and values computed by 2 commercial computer algorithms. CONCLUSIONS We observed large differences in electrocardiographic heart rate, interval, and axis reference ranges in this study compared with those reported previously and with reference ranges in general use. We also observed a large influence of age and sex upon normal values. Very large cohorts are required to fully assess age- and sex-related variation of reference ranges. Electrocardiographic reference ranges should be modernized.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of reference ranges using medical laboratory date

In order to have reliable reference ranges and to minimize the effects of variables such as the procedure of specimen collection, geographical location, dietary habits, life style and possible errors during the performance of tests, it  is recommended that each medical laboratory establish it's own reference values. Idealy, the reference ranges Should be determined by analysis of specimens from...

متن کامل

Electrocardiographic characteristics of neurocirculatory asthenia during everyday activities.

We describe the electrocardiographic changes during everyday activities recorded by ambulatory electrocardiographic monitoring in 67 patients with neurocirculatory asthenia. The findings were compared with the results of ambulatory monitoring in 33 healthy controls. We observed episodes of sinus tachycardia > 120/min unrelated to effort in 60 of the patients, 35 had frequent episodes of pronoun...

متن کامل

A consistent reference frame for ambulatory blood pressure monitoring is found in different populations.

This study investigated the consistency of a reference frame for ambulatory pressure monitoring, which using various approaches was determined in two different populations. The two reference groups were 718 subjects randomly selected from the population and 895 bank employees. The reference values derived in these two groups were subsequently tested in 591 untreated hypertensive patients. The a...

متن کامل

A Description of Reference Ranges for Organic Acids in Urine Samples from A Pediatric Population in Iran

Background: Organic acids refer to a family of compounds that are intermediates in a variety of metabolic pathways. Many organic acids are present in urine from clinically normal individuals. Elevated levels of urine organic acids cause to the organic acidurias, disorders in which some metabolic pathways in organic acid metabolism are blocked. The present work identified major and minor urinary...

متن کامل

The Corrected Orthogonal Electrocardiogram

A NUMBER of reports on normal ranges of corrected orthogonal electrocardiographic measurements have appeared in the literature.'-12 They were derived, however, from limited numbers of subjects and the types of electrocardiographic and vectorcardiographic measurements varied largely from one study to another. The reported results are therefore not always strictly comparable. In spite of these li...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of electrocardiology

دوره 40 3  شماره 

صفحات  -

تاریخ انتشار 2007