Application of PI controller based DSTATCOM for improving the power quality in a power system network with induction furnace load
نویسندگان
چکیده
This paper presents the application of DSTATCOM in a distribution network with induction furnace load. Induction furnace is one of the common types of load used in industries like the steel industry. The problem with the induction furnace load is the generation of appreciable amount of harmonic distortion. This distortion results due to the design and operation of the induction furnace. This harmonic distortion can even affect the performance of other loads connected in the system. DSTATCOM is a shunt connected custom power device to improve the power quality. It does so by injecting a compensating current into the power system network. In this paper, the SIMULINK model representing the application of DSTATCOM with PI controller for reducing the harmonic distortion of the distribution network with induction furnace load is presented.
منابع مشابه
Analysis of Different Loads with Multi-techniques Using D- Statcom
Due to the rapid growth of non-linear loads, such as power electronic control equipments and Electric arc furnace (EAF) power quality problems such as harmonics and voltage flicker are introduced in the power system. It occurs because of the time-varying and nonlinear behaviour of the Load. Arc furnaces are used in industries for induction heating and welding. Hence an Electric arc furnace mode...
متن کاملApplication of ANN Technique for Interconnected Power System Load Frequency Control (RESEARCH NOTE)
This paper describes an application of Artificial Neural Networks (ANN) to Load Frequency Control (LFC) of nonlinear power systems. Power systems, such as other industrial processes, have parametric uncertainties that for controller design had to take the uncertainties in to account. For this reason, in the design of LFC controller the idea of robust control theories are being used. To improve ...
متن کاملComparative Power Quality Analysis of Different DSTATCOM Topologies
This paper presents the three topologies of three-phase four-wire DSTATCOM for reduction of harmonics, reactive power compensation, increasing power factor, which occur due to a nonlinear load, environment problem and polluted grid. The performances of the above topologies have been compared for the magnitude of source current, power factor improvement, DC-link voltage regulation, and total har...
متن کاملDesign of Fuzzy Logic Based PI Controller for DFIG-based Wind Farm Aimed at Automatic Generation Control in an Interconnected Two Area Power System
This paper addresses the design procedure of a fuzzy logic-based adaptive approach for DFIGs to enhance automatic generation control (AGC) capabilities and provide better dynamic responses in multi-area power systems. In doing so, a proportional-integral (PI) controller is employed in DFIG structure to control the governor speed of wind turbine. At the first stage, the adjustable parameters of ...
متن کاملA Coordinated Control Scheme for Improving Voltage Quality Using Power Electronics Interfaced DGs
Recently, increasing of non-linear loads in the power distribution network has been increased harmonics in these networks. The harmonics problems get worse and complicated by installation of power factor correction capacitors and filters. But the Distributed Generations (DGs) interface inverters with properly control can help to improve power quality, harmonic compensation and voltage unbalance...
متن کامل