BACKGROUND Screw loosening of implant restorations continues to be a complication in implant prosthodontics. Screw joints are subjected to a loss of initially applied torque because of friction and component misfit. It has been suggested that the loss of applied torque is less in machined metal abutments than in cast plastic abutments. PURPOSE This study compared the loss of applied torque (detorque) values in machined titanium and in cast UCLA-type abutments for external hex abutment/implant interface. MATERIALS AND METHODS Four groups of 12 samples each were evaluated: (1) machined titanium abutments, (2) premachined palladium abutments cast with palladium, (3) plastic abutments cast with nickel-chromium, and (4) plastic abutments cast with cobalt-chromium. Each abutment was torqued to 30 Ncm according to the manufacturer's instructions and detorqued three times. The mean loss of applied torque (detorque) was recorded as a percentage of the torque applied. Group means were calculated and compared using ANOVA and Tukey's LSD test. RESULTS Mean detorque values were (1) 92.3 +/- 2.9%, (2) 81.6 +/- 5.0%, (3) 86.4 +/- 4.6%, and (4) 84.0 +/- 7.0%. Machined abutments demonstrated significantly greater detorque values compared with all cast groups (p < 0.05). No significant differences were found among cast groups. CONCLUSION Machined abutments retained a significantly greater percentage of torque compared with cast abutments. Casting procedures decrease the percentage of applied torque, which may influence final screw joint stability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Abutment Connection Type and Cyclic Loading on Removal Torque Value

Background and Aim: Maintaining the primary torque of the abutment screw is a common problem related to implant-supported restorations; a failure in this respect often leads to screw loosening. The abutment screw plays a critical role in the long-term stability of restorations. This study aimed to assess the effect of two abutment connection types with and without cyclic loading on removal torq...

متن کامل

Measurement of the dimensions and abutment rotational freedom of gold-machined 3i UCLA-type abutments in the as-received condition, after casting with a noble metal alloy and porcelain firing.

STATEMENT OF PROBLEM Laboratory processing of implant-supported prostheses may alter the surface of the abutment in contact with the implant head and thus the interface fit. PURPOSE This study assessed changes at the implant interface of gold-machined UCLA abutments after casting and porcelain baking in the case of single-tooth restorations. MATERIAL AND METHODS The depth (d) and width (w) ...

متن کامل

Effect of Casting Procedure on Screw Loosening of Ucla Abutment in Two Implant-abutment Connection Systems

Since Bra�nemark et al published the results of a 10-year study on osseointegration in 1977, dental implants have increasingly been used to replace missing teeth. The use of osseointegrated implants had become a successful procedure for the treatment of complete, partial edentulism, and single-tooth replacements in both the anterior and posterior regions of the mouth. Although improvements in m...

متن کامل

Effect of Cast Rectifiers on the Marginal Fit of Ucla Abutments

OBJECTIVES This study assessed the effect of cast rectifiers on the marginal misfit of cast UCLA abutments compared to premachined UCLA abutments. The influence of casting and porcelain baking on the marginal misfit of these components was also investigated. METHODS Two groups were analyzed: test group - 10 cast UCLA abutments, finished with cast rectifier and submitted to ceramic application...

متن کامل

Screw loosening of different UCLA-type abutments after mechanical cycling

Aim: To evaluate the loss of applied torque (detorque) values in cast and pre-machined abutments for external hex abutment/implant interface of single implant-supported prostheses subjected to mechanical cycling. Methods: Ten metal crowns were fabricated using two types of UCLA abutments: cast and pre-machined with metal base in NiCrTi alloy and tightened to regular external hex implants with a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of prosthodontics : official journal of the American College of Prosthodontists

دوره 15 2  شماره 

صفحات  -

تاریخ انتشار 2006