Real-time gas-correlation imaging employing thermal background radiation.

نویسندگان

  • J Sandsten
  • P Weibring
  • H Edner
  • S Svanberg
چکیده

Real-time imaging of gas leaks was demonstrated using an IR camera employing outdoor thermal background radiation. Ammonia, ethylene and methane detection was demonstrated in the spectral region 7-13 microm. Imaging was accomplished using an optical filter and a gas-correlation cell matching the absorption band of the gas. When two gases, such as ammonia and ethylene, are absorbing in the same wavelength region it is possible to isolate one for display by using gas-correlation multispectral imaging. Results from a field test on a leaking gas tanker are presented as QuickTime movies. A detection limit of 200 ppm x meter for ammonia was accomplished in this setup when the temperature difference between the background and the gas was 18 K and the frame rate was 15 Hz.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between single and double flow plane solar heaters considering gas radiation effect

ABSTRACT: In this paper, the thermal characteristics of single and double flow plane solar heaters with radiating working gas were analyzed and compared by numerical analysis for the first time. The laminar mixed convection gas flow in the heaters was numerically simulated by the CFD method using the finite volume technique. The set of governing equations included the conservation of mass, mome...

متن کامل

Simulation of a Neutron Detector for Real Time Imaging Applications

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...

متن کامل

An Information System Supporting Electromagnetic Compatibility and Radiation Risk Management in the Modern Hospital

Background information: Electromagnetic radiation is the transmission of energy in the form of waves having an electric and magnetic component. Almost all forms of electromagnetic radiation, which constitute the electromagnetic spectrum, such as radio waves, visible, infrared, and uliraviolet light, X-rays and gamma rays, are employed in the contemporary Hospital. There are some crucial decisio...

متن کامل

Evaluation of Thresholding Based Noncontact Respiration Rate Monitoring using Thermal Imaging

A noncontact method for respiration rate monitoring using thermal imaging was developed and evaluated. Algorithms to capture images, detect the location of the face, locate the corners of the eyes from the detected face and thereafter locate the tip of the nose in each image were developed. The amount of emitted infrared radiation was then determined from the detected tip of the nose. Signal pr...

متن کامل

Experimental evaluation of thermal stability of PS- MWCNT nanocomposite as a real-time dosimeter

Introduction: Carbon nanotubes (CNTs) are ideal reinforcing fillers for a polymer matrix, because of their nanometer size, high aspect ratio and, more importantly, their excellent mechanical strength, and electrical and thermal conductivity. The CNTs are categorized into two groups: SWCNT and MWCNT. MWCNTs would have diameters ranging from 2 to 100 nm and lengths of up to tens ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics express

دوره 6 4  شماره 

صفحات  -

تاریخ انتشار 2000