Open Versus Closed Hearing-Aid Fittings: A Literature Review of Both Fitting Approaches
نویسندگان
چکیده
One of the main issues in hearing-aid fittings is the abnormal perception of the user's own voice as too loud, "boomy," or "hollow." This phenomenon known as the occlusion effect be reduced by large vents in the earmolds or by open-fit hearing aids. This review provides an overview of publications related to open and closed hearing-aid fittings. First, the occlusion effect and its consequences for perception while using hearing aids are described. Then, the advantages and disadvantages of open compared with closed fittings and their impact on the fitting process are addressed. The advantages include less occlusion, improved own-voice perception and sound quality, and increased localization performance. The disadvantages associated with open-fit hearing aids include reduced benefits of directional microphones and noise reduction, as well as less compression and less available gain before feedback. The final part of this review addresses the need for new approaches to combine the advantages of open and closed hearing-aid fittings.
منابع مشابه
The Outcomes of Hearing Aid Fittings in Developed and Developing Countries
With regard to the practice of hearing aid fittings, presently there is no unanimous concurrence among audiologists and speech-language pathologists as to what constitutes a successful hearing aid fitting. Many audiologists’ beliefs on successful fittings often lie with only one of the following levels namely impairment level, activity level, participation level, satisfaction level, health rela...
متن کاملRemote hearing aid fitting: Tele-audiology in the context of Brazilian Public Policy
INTRODUCTION Currently, the Brazilian government has certificated nearly 140 specialized centers in hearing aid fittings through the Brazilian National Health System (SUS). Remote fitting through the Internet can allow a broader and more efficient coverage with a higher likelihood of success for patients covered by the SUS, as they can receive fittings from their own homes instead of going to ...
متن کاملEvaluation of an in-situ output probe-microphone method for hearing aid fitting verification.
Several hearing aid prescription procedures specify frequency gain functions in terms of the desired levels of amplified speech. The most direct method for verifying hearing aid fittings based on these procedures requires a measurement of amplified speech in the ear canal. This paper describes the evaluation of a probe microphone measurement procedure designed to measure amplified speech to ver...
متن کاملInitial-fit approach versus verified prescription: comparing self-perceived hearing aid benefit.
BACKGROUND Despite evidence suggesting inaccuracy in the default fittings provided by hearing aid manufacturers, the use of probe-microphone measures for the verification of fitting accuracy is routinely used by fewer than half of practicing audiologists. PURPOSE The present study examined whether self-perception of hearing aid benefit, as measured through the Abbreviated Profile of Hearing A...
متن کاملHearing aids: indications, technology, adaptation, and quality control
Hearing loss can be caused by a number of different pathological conditions. Some of them can be successfully treated, mainly by surgery, depending on the individual's disease process. However, the treatment of chronic sensorineural hearing loss with damaged cochlear structures usually needs hearing rehabilitation by means of technical amplification. During the last two decades tremendous impro...
متن کامل