Examiner's finger-mounted fetal tissue oximetry.
نویسندگان
چکیده
The best way to assess fetal condition is to observe the oxygen status of the fetus (as well as to assess the condition of infants, children, and adults). Previously, several fetal oximeters have been developed; however, no instrument has been utilized in clinical practice because of the low-capturing rate of the fetal oxygen saturation. To overcome the problem, we developed a doctor's finger-mounted fetal tissue oximeter, whose sensor volume is one hundredth of the conventional one. Additionally, we prepared transparent gloves. The calculation algorithm of the hemoglobin concentration was derived from the light propagation analysis based on the transport theory. We measured neonatal and fetal oxygen saturation (StO₂) with the new tissue oximeter. Neonatal StO₂ was measured at any position of the head regardless of amount of hair. Neonatal StO₂ was found to be around 77%. Fetal StO₂ was detected in every position of the fetal head during labor regardless of the presence of labor pain. Fetal StO₂ without labor pain was around 70% in the first stage of labor and around 60% in the second stage of labor. We concluded that our new concept of fetal tissue oximetry would be useful for detecting fetal StO₂ in any condition of the fetus.
منابع مشابه
Examiner's finger-mounted fetal tissue oximetry: a preliminary report on 30 cases.
OBJECTIVE To describe preliminary experience with a finger-mounted fetal tissue oximetry probe during the 2nd stage of labor. MATERIALS AND METHODS A total of 30 term pregnant women without pregnancy complications were recruited. We measured fetal tissue oxygen saturation (FtO2) by using a finger-mounted fetal tissue oximetry during cervical examinations in the 2nd stage of labor. The data ca...
متن کاملCraniofacial tissue oxygen saturation is associated with blood pH using an examiner's finger-mounted tissue oximetry in mice.
Although fetal scalp blood sampling is an examination to assess fetal acidosis during the intrapartum period, it has not been widely used by obstetricians because of its invasiveness. We have developed a small, portable oximetry with a sensor attached to the examiner's finger. Our previous report using this oximetry concluded that fetal head tissue oxygen saturation (StO 2 StO2 ) correlated wit...
متن کاملExaminer's finger-mounted near-infrared spectroscopy is feasible to analyze cerebral and skeletal muscle oxygenation in conscious Chihuahuas.
To measure regional saturation of oxygen ( rSO 2 ) of hemoglobin and total hemoglobin index (HbI) in the brain (through the molera of the head) and skeletal muscle (musculus gracilis) of conscious Chihuahua dogs using an examiner’s finger-mounted near-infrared spectroscopy (NIRS) device, Toccare, we investigated brain and skeletal muscle NIRS in 48 Chihuahuas without severe disease. To measure ...
متن کاملTrans-abdominal monitoring of fetal arterial blood oxygenation using pulse oximetry.
Pulse oximetry (oxygen saturation monitoring) has markedly improved medical care in many fields, including anesthesiology, intensive care, and newborn intensive care. In obstetrics, fetal heart rate monitoring remains the standard for intrapartum assessment of fetal well being. Fetal oxygen saturation monitoring is a new technique currently under development. It is potentially superior to elect...
متن کاملComparison of SpO2 values from different fingers of the hands
Pulse oximetry is a frequently used tool in anesthesia practice. Gives valuable information about arterial oxygen content, tissue perfusion and heart beat rate. In this study we aimed to provide the comparison of peripheral capillary hemoglobin oxygen saturation (SpO2) values among every finger of the two hands. Thirty-seven healthy volunteers from operative room stuffs between the ages of 18-3...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 19 6 شماره
صفحات -
تاریخ انتشار 2014