A comparative study of Endoflare-Hero Shaper and Mtwo NiTi instruments in the preparation of curved root canals.

نویسندگان

  • M Veltri
  • A Mollo
  • L Mantovani
  • P Pini
  • P Balleri
  • S Grandini
چکیده

AIM To analyse the shaping ability of two new NiTi rotary systems in molar curved canals. METHODOLOGY Thirty molar root canals with curvatures from 24 degrees to 69 degrees were divided into two groups that were balanced in terms of curvature. The canals in one group were shaped using the Mtwo (Sweden & Martina, Padova, Italy) and the canals in the other group using the Endoflare-Hero Shaper (Micro-Mega, Besançon, France) in a modified sequence. Pre- and post-instrumentation X-rays were taken using a radiographic platform, with a contrast medium being used to enhance canal opacity. The dentine removed at five positions along the canals, the symmetry of canal shaping and the presence of aberrations were analysed through computer-aided measurements. The instrument failures, the working time and the changes in working length were also recorded. The Mann-Whitney U-test was used for statistical analyses. RESULTS Both systems produced uniform dentine removal and symmetrical canal shapes; there was no significant difference between the systems (P > 0.05). In the apical region, preparations were centred in the canal. A mean loss of working length of 0.55 mm for Mtwo and 0.58 mm for Endoflare-Hero Shaper was detected, with no significant differences between the instruments (P > 0.05). No aberrations were seen and no instruments separated. The mean working time was 124.4 s for the Mtwo system and 141.3 s for the Endoflare-Hero Shaper but this difference was not statistically significant (P > 0.05). CONCLUSION The systems tested in this study were effective in shaping curved canals in extracted teeth.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Shaping Ability of NiTi Rotary versus Stainless-Steel Hand Instruments in Curved Root Canals of Extracted Teeth

Introduction: The purpose of this in-vitro study was to compare shaping ability of NiTi rotary Mtwo and FlexMaster with stainless steel hand K-Flexofile in curved root canals of extracted teeth. Materials and Methods: Mesiobuccal canals of 45 mandibular molar teeth were balanced into three groups of 15 each, with respect to the Schneider angle, canal access angle, height, dis-tance and radiu...

متن کامل

Detection of Procedural Errors during Root Canal Instrumentation using Cone Beam Computed Tomography

BACKGROUND This study investigated procedural errors made during root canal preparation with nickel-titanium (NiTi) instruments, using cone beam computed tomography (CBCT) imaging method. MATERIALS AND METHODS A total of 100 human mandibular molars were divided into five groups (n = 20) according to the NiTi system used for root canal preparation: Group 1 - BioRaCe, Group 2 - K3, Group 3 - Pr...

متن کامل

Shaping ability of progressive versus constant taper instruments in curved root canals of extracted teeth.

AIM To compare the shaping ability of progressive versus constant taper shaft instruments in curved root canals of extracted human teeth. METHODOLOGY A total of 40 root canals of mandibular molars with curvatures ranging between 20 degrees and 40 degrees were divided into two groups of 20 canals each and embedded in a muffle system. The root canals sectioned horizontally at three levels befor...

متن کامل

Cone-beam computed tomography analysis of curved root canals after mechanical preparation with three nickel-titanium rotary instruments

Cone beam computed tomography is a 3-dimensional high resolution imaging method. The purpose of this study was to compare the effects of 3 different NiTi rotary instruments used to prepare curved root canals on the final shape of the curved canals and total amount of root canal transportation by using cone-beam computed tomography. A total of 81 mesial root canals from 42 extracted human mandib...

متن کامل

Assessment of cleaning efficacy of Mtwo NiTi rotary files and Hand K-files: A comparative in-vitro study

NTRODUCTION The goals of root canal therapy are to remove infected and necrotic pulpal tissue remnants, shape the root canal system to facilitate irrigation and medication and adequate sealing using obturation materials. 1 Rotary instruments enhance the quality of obturation by providing conical shape to the root canal. Nickle titanium (NiTi) alloy instruments inherent flexibility that allows t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International endodontic journal

دوره 38 9  شماره 

صفحات  -

تاریخ انتشار 2005