Intraoperative OCT-Assisted DMEK: 14 Consecutive Cases.

نویسندگان

  • Alain Saad
  • Emmanuel Guilbert
  • Alice Grise-Dulac
  • Patrick Sabatier
  • Damien Gatinel
چکیده

PURPOSE To describe the utility of a new intraoperative optical coherence tomographer (OCT) to evaluate endothelio-Descemet graft orientation during Descemet membrane endothelial keratoplasty (DMEK) procedures. METHODS Prospective, observational, and single-center pilot case series including 14 eyes of 14 patients consecutively scheduled for DMEK surgery. After injecting the graft into the anterior chamber, the graft orientation was assessed with the help of anterior segment OCT. The surgical time and unfolding time were measured. The postoperative measurements included best-corrected visual acuity, central pachymetry, and specular microscopy at 1 month. RESULTS Using the OCT images, it was possible to evaluate the graft orientation in all cases. The mean unfolding time was 6.1 ± 3.0 minutes, the mean best-corrected visual acuity was 0.3 ± 0.3 logarithm of the minimum angle of resolution, the mean decrease in central pachymetry was 213 ± 177 μm, and the mean central endothelial cell count was 1906 ± 319 cells per square millimeter. CONCLUSIONS Live intraoperative OCT is useful to visualize and assess graft orientation in DMEK surgery. It enables faster graft positioning with less graft manipulation in the presence of severe corneal edema.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Visualization of precut DSAEK and pre-stripped DMEK donor corneas by intraoperative optical coherence tomography using the RESCAN 700

BACKGROUND To report the feasibility of intraoperative spectral domain optical coherence tomography (OCT) using the RESCAN 700 for the visualization and evaluation of precut Descemet's stripping automated endothelial keratoplasty (DSAEK) and prestripped Descemet's membrane endothelial keratoplasty (DMEK) donor tissue. METHODS Precut DSAEK (n = 11), prestripped DMEK (n = 4) preserved in a view...

متن کامل

Descemet membrane endothelial keratoplasty in cases with existing scleral-sutured and iris-sutured intraocular lenses

BACKGROUND To report two cases of Descemet Membrane Endothelial Keratoplasty (DMEK) in patients with existing scleral-fixated and iris-fixated intraocular lenses (sf-IOL and if-IOL, respectively). CASE PRESENTATION DMEK procedures were performed on a 49-year-old woman with a pre-existing sf-IOL (case 1) and a 69-year-old woman with a pre-existing if-IOL (case 2) in order to treat secondary co...

متن کامل

Macular Surgery Using Intraoperative Spectral Domain Optical Coherence Tomography

PURPOSE To report the use of intraoperative spectral domain optical coherence tomography (SD-OCT) for detecting anatomical changes during macular surgery. METHODS In a consecutive case series, 32 eyes of 32 patients undergoing concurrent pars plana vitrectomy and intraoperative SD-OCT for macular hole (MH), epiretinal membrane (ERM) and vitreomacular traction (VMT) were enrolled. Intraoperati...

متن کامل

Clinical Outcomes of Descemet Membrane Endothelial Keratoplasty During the Surgeon Learning Curve Versus Descemet Stripping Endothelial Keratoplasty Performed at the Same Time

PURPOSE To compare outcomes after Descemet Membrane Endothelial Keratoplasty (DMEK) and traditional Descemet Stripping Endothelial Keratoplasty (DSEK) during the surgeon's DMEK learning curve in a prospective, non-randomized, consecutive, interventional case series. METHODS Consecutive patients presenting to the university eye clinics and undergoing endothelial keratoplasty were included. Dat...

متن کامل

Standardization of the Descemet membrane endothelial keratoplasty technique: Outcomes of the first 450 consecutive cases.

OBJECTIVES To evaluate the clinical outcome of the first 450 consecutive cases after Descemet membrane endothelial keratoplasty (DMEK), as well as the effect of standardization of the technique. MATERIAL AND METHODS Comparison between 3 groups: Group I: (cases 1-125), as the extended learning curve; Group II: (cases 126-250), transition to technique standardization; Group III: (cases 251-450)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Cornea

دوره 34 7  شماره 

صفحات  -

تاریخ انتشار 2015