The influence of long-term corneal contact lens wearing on the stability and quality of tear film in Qinghai

نویسندگان

  • Xiaorong Xin
  • Tianxiang Gong
  • Ying Hong
  • Hong Dang
چکیده

This study was designed to explore the influence of long-term corneal contact lens (CL) wearing on the stability and quality of tear film in Qinghai. Thirty subjects with CL over five years and thirty myopia subjects without CL as control were recruited in our study. Basic tear secretion test, tear film break-up time (TBUT), and corneal fluorescein staining were determined. For further evaluating the quality of tear film of two groups, the mucin levels including mucin 1 (MUC1) and mucin 5AC (MUC5AC) were measured by enzyme-linked immunosorbent assay (ELISA), meanwhile MUC1 and MUC5AC mRNA expression were processed by real-time polymerase chain reaction (RT-PCR) after samples were collected. Compared with control group, basic tear secretion and TBUT decreased, obvious corneal fluorescein staining presented in CL group. The mean protein quantity of MUC1 and MUC5AC in CL group (1.1612±0.2119 ng/ml, 1.6731±0.2457 ng/ml respectively) was less than that of control group (1.2369±0.1825 ng/ml and 1.7892±0.2461 ng/ml respectively), there were significant differences between the two groups (t=2.098, P=0.038; t=2.586, P=0.011 respectively). Both the mRNA expression of MUC1 and MUC5AC in the CL group (1.3944±0.1212 and 1.622±0.1988 respectively) decreased in comparison with control group (1.4630±0.1028 and 1.7056±0.1638 respectively), significant differences was observed between the two groups (t=3.343, P=0.001; t=2.514, P=0.013 respectively). These results suggest that long-term CL wearing in Qinghai might pose an impact on the stability and quality of tear film.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tear film, contact lens, and patient factors associated with corneal staining.

PURPOSE The purpose of this study was to examine ocular surface and tear film, contact lens, care solution, medical, and patient-related factors that are associated with corneal staining in contact lens wearers. METHODS In this cross-sectional/nested case-control study, in addition to the assessment of corneal staining with fluorescein, a variety of tear film and ocular surface, contact lens,...

متن کامل

Objective and subjective assessing efficacy of a lubricating drop in eyes wearing silicone hydrogel contact lenses

PURPOSE To investigate the effect of a lubricating drop on optical quality, tear film stability, and subjective symptoms in individuals wearing silicone hydrogel contact lens. METHODS In this one-day, prospective single-center clinical study, Pre-lens Tear Deformation Time (PL-TDT), Root-Mean-Square (RMS) of Low Order Aberrations (LOA) and High Order Aberrations (HOA), individual twelve Zerni...

متن کامل

Tear film inflammatory mediators during continuous wear of contact lenses and corneal refractive therapy.

OBJECTIVES To study changes in tear film inflammatory mediators following continuous wear of silicone-hydrogel lenses and corneal refractive therapy with reverse geometry contact lenses. DESIGN A prospective, case-control study. METHODS Twenty-eight subjects had worn silicone-hydrogel lenses on a 30-night continuous wear basis. Thirty-two subjects had worn corneal refractive therapy lenses ...

متن کامل

Differences in clinical parameters and tear film of tolerant and intolerant contact lens wearers.

PURPOSE To determine whether intolerance to contact lens wear is attributable to clinical or protein characteristics of the tear film. METHODS Thirty-eight subjects participated; 20 were successful contact lens wearers and 18 had discontinued contact lens wear because of discomfort. Baseline tear film (no lens wear) was analyzed with a range of clinical measurements and protein analyses (lact...

متن کامل

Curvature sensor for the measurement of the static corneal topography and the dynamic tear film topography in the human eye.

A system to measure the topography of the first optical surface of the human eye noninvasively by using a curvature sensor is described. The static corneal topography and the dynamic topography of the tear film can both be measured, and the topographies obtained are presented. The system makes possible the study of the dynamic aberrations introduced by the tear film to determine their contribut...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016