Modelling and Analysis on Biomechanical Dynamic Characteristics of Knee Flexion Movement under Squatting

نویسندگان

  • Jianping Wang
  • Kun Tao
  • Huanyi Li
  • Chengtao Wang
چکیده

The model of three-dimensional (3D) geometric knee was built, which included femoral-tibial, patellofemoral articulations and the bone and soft tissues. Dynamic finite element (FE) model of knee was developed to simulate both the kinematics and the internal stresses during knee flexion. The biomechanical experimental system of knee was built to simulate knee squatting using cadaver knees. The flexion motion and dynamic contact characteristics of knee were analyzed, and verified by comparing with the data from in vitro experiment. The results showed that the established dynamic FE models of knee are capable of predicting kinematics and the contact stresses during flexion, and could be an efficient tool for the analysis of total knee replacement (TKR) and knee prosthesis design.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immediate effect of Mulligan knee taping on pain, knee dynamic valgus, and landing kinetic in physically active female with patellofemoral pain

 Aims and background: Inappropriate kinetic and kinematic are considered as effective factors in knee injuries especially patellofemoral pain. The aim of this study was to investigate the immediate effect of Mulligan taping on knee dynamic valgus, maximum knee flexion angle, the maximum ground reaction force, time to stabilization and pain in physically active female with patellofemoral pain an...

متن کامل

Squatting-Related Tibiofemoral Shear Reaction Forces and a Biomechanical Rationale for Femoral Component Loosening

Previous gait studies on squatting have described a rapid reversal in the direction of the tibiofemoral joint shear reaction force when going into a full weight-bearing deep knee flexion squat. The effects of such a shear reversal have not been considered with regard to the loading demand on knee implants in patients whose activities of daily living require frequent squatting. In this paper, th...

متن کامل

Does joint line elevation after revision knee arthroplasty affect tibio-femoral kinematics, contact pressure or collateral ligament lengths? An in vitro analysis

INTRODUCTION Correct restoration of the joint line is generally considered as crucial when performing total knee arthroplasty (TKA). During revision knee arthroplasty however, elevation of the joint line occurs frequently. The general belief is that this negatively affects the clinical outcome, but the reasons are still not well understood. MATERIAL AND METHODS In this cadaveric in vitro stud...

متن کامل

Changes of the Patellar Tendon Moment arm Length in Different Knee Angles: A Biomechanical in Vivo Study

Patellar tendon moment arm length (PTma) changes at different knee flexion angles have not been determined in invivo studies. We aimed to determine PTma in four different knee angles using Magnetic Resonance Imaging (MRI) topredict in vivo changes in the moment arm length from different knee angles during running.PTma was measured as the perpendicular distance from muscle–tend...

متن کامل

Biomechanical evaluation of degree of freedom of movements of a novel high-flexion knee for its suitability in eastern lifestyles.

The total knee arthroplasty is the end-stage surgical procedure for pain relief in degenerative diseases such as arthritis. There have been many models designed in the five to six decades of arthroplasty history. This research has helped us in designing a new artificial high-flexion knee, which emphasizes a high flexion-extension range of over 125 degrees. This range provides comfort while squa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014