Assessment of reprocessed arthroscopic shaver blades.

نویسندگان

  • Jonathan S King
  • Marilyn M Pink
  • Christopher M Jobe
چکیده

PURPOSE The purpose of this study was to evaluate the level of contaminants on, as well as the quality of, reprocessed shaver blades. METHODS We assessed 7 new shaver blades and 27 shaver blades that had been reprocessed with mechanical cleaning, functional testing, and sterilization with ethylene oxide. A spectrophotometer measured the amount of nucleic acid and protein. The blade quality was assessed by photographing the blades with magnification and determining the percentage of damage present on each blade. A subset of shaver blades were then used to cut meniscal tissue, and the cut surface was measured for smoothness by image processing and automated laser scanning cytometry. In evaluation of the meniscus, for the subset of shavers, an image processing value of 1 indicates a smooth, straight line, and values lower than 1 reflect deviations in the cut surface (the closer the value is to 1, the smoother the surface). Laser scanning cytometry values indicate the percentage of irregularities in the cut surface (the lower the value is, the smoother the surface). RESULTS Of the 27 reprocessed shaver blades, 13 (48%) had detectable levels of protein and 17 (63%) had detectable levels of nucleic acid. On the reprocessed shaver blades, protein levels ranged from 2.43 microg to 60 microg and nucleic acid levels ranged from 0.40 microg to 3.5 microg. No new shaver blade had contaminants. Twenty reprocessed shaver blades had been manufactured with teeth and could be evaluated for visible damage. Of these, 10 had 1% to 25% damage, 5 had 26% to 50% damage, 3 had 51% to 75% damage, and 2 had 76% to 100% damage. The new blades had no visible damage. Image processing revealed smoothness of the surface cut with new shaver blades, yielding values of 1 +/- 0.12, whereas the values for reprocessed shaver blades ranged from 0.62 +/- 0.02 to 1 +/- 0.07. Laser scanning cytometry values ranged from 3.3% to 7.1% for the new blades as compared with 5.8% to 20.0% for the reprocessed blades. CONCLUSIONS Of the reprocessed shaver blades, 48% had detectable levels of protein and 63% had detectable levels of nucleic acid. All of the reprocessed blades visually evaluated showed some level of damage or wear, whereas no new blade had such damage. In addition, menisci cut with reprocessed shavers showed rougher edges than did menisci cut with new shavers. CLINICAL RELEVANCE To make an informed decision regarding the use of reprocessed shaver blades, surgeons will want to know the level of contamination on, and the quality of, reprocessed shaver blades.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reprocessed arthroscopic shavers: evaluation of sharpness and function in a cadaver model.

This study was designed to test limited arthroscopic shaver reuse following reprocessing and to compare the functional performance between new and reprocessed arthroscopic shavers in arthroscopic procedures using fresh cadaveric knees. A trial using arthroscopic procedures (menisectomy, synovectomy, and debridements) was conducted by experienced surgeons using cadaveric knees to determine wheth...

متن کامل

Clinical evaluation of reprocessed blades in LASIK.

PURPOSE To evaluate outcome and complications in LASIK with reprocessed blades. METHODS Retrospective analysis of patients' charts submitted to complete custom LASIK from January 2004 to June 2005. Inclusion criteria comprised surgical description of blade use and minimum follow-up of 1 month. The blade was reprocessed following a clinic protocol, from 1 to 3 times (reprocessed group) and res...

متن کامل

Allergic nickel dermatitis caused by shaving: case report and assessment of nickel release from an electric shaver.

Fig. 1. Allergic nickel dermatitis caused by nickel release from an electric shaver. Nickel allergy is frequent in adult Danes and dermatitis patients (1, 2). The high prevalence is mostly explained by consumer exposure to products that release nickel, e.g. watches, jewellery, buttons, zips, rivets and mobile phones (3–8). It has been debated whether classic dry electric shavers may cause nicke...

متن کامل

Meniscal debridement with an arthroscopic radiofrequency wand versus an arthroscopic shaver: comparative effects on menisci and underlying articular cartilage.

PURPOSE Meniscal debridement with an arthroscopic radiofrequency (RF) wand versus an arthroscopic shaver and their comparative effects on menisci and underlying articular cartilage were studied. METHODS When repair is not feasible, degenerative or post-traumatic meniscal tears often need debridement. Six fresh bovine knees were harvested, the tibial plateau was dissected free from the femoral...

متن کامل

Subcutaneous emphysema, pneumomediastinum, and potentially life-threatening tension pneumothorax. Pulmonary complications from arthroscopic shoulder decompression.

Subcutaneous emphysema, pneumomediastinum, and tension pneumothorax are previously unreported complications of shoulder arthroscopy with subacromial decompression. Three patients developed extensive subcutaneous emphysema, pneumomediastinum, and bilateral tension pneumothorax during or immediately after shoulder arthroscopy with subacromial decompression. The procedure was terminated and approp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association

دوره 22 10  شماره 

صفحات  -

تاریخ انتشار 2006