A Study of Kruppa’s Equation for Camera Self-calibration
نویسندگان
چکیده
In this paper we discuss the Kruppa’s equation, which is widely known as the first camera self-calibration method. The classical and the simplified version of the method are of our interest. We have analyzed it based on how it is derived. As Kruppa’s equation works based on the image of the absolute conic, which is an imaginary conic, we have found that the use of circular points at infinity was missed in the classical Kruppa’s in generating the imaginary conic. We have pointed out that the concept of degenerate point conic in deriving the simplified version is one of the reasons of degeneracy. Other than that, we also found some other inaccuracies of the derivation. For the future use as well as the improvement of the method, we have proposed possible solutions for it.
منابع مشابه
Translation of "Zur Ermittlung eines Objektes aus zwei Perspektiven mit innerer Orientierung" by Erwin Kruppa (1913)
Erwin Kruppa’s 1913 paper, Erwin Kruppa, “Zur Ermittlung eines Objektes aus zwei Perspektiven mit innerer Orientierung”, Sitzungsberichte der Mathematisch-Naturwissenschaftlichen Kaiserlichen Akademie der Wissenschaften, Vol. 122 (1913), pp. 1939–1948, which may be translated as “To determine a 3D object from two perspective views with known inner orientation”, is a landmark paper in Computer V...
متن کاملCamera Self-calibration in the AUV Monocular Vision Navigation and Positioning
Camera calibration is essential to obtain 3D information from 2D image, for underwater camera self-calibration, because the linear model can not accurately describe the imaging geometry of real cameras, the underwater camera nonlinear model and its calibration method are studied. According to the relationship between underwater and air in the camera focal length, principal point and no vertical...
متن کاملNew approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras
Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...
متن کاملA Rigorous and Flexible Calibration Method for Digital Airborne Camera Systems
This paper presents a novel family of rigorous and flexible mathematical self-calibration additional parameters (APs) for airborne camera calibration. It is pointed out, that photogrammetric self-calibration can – to a very large extent – be considered as a function approximation problem in mathematics. Based on the mathematical approximation theory, we suggest that Fourier series (trigonometri...
متن کاملA Case Against Kruppa's Equations for Camera Self-Calibration
We consider the self-calibration problem for perspective cameras, and especially the classical Kruppa equation approach. It is known that for several common types of camera motion, self-calibration is degenerate, which manifests itself through the existence of ambiguous solutions. In a previous paper, we have studied these critical motion sequences and have revealed their importance for practic...
متن کامل