Investigation of a novel algorithm for synchronized left-ventricular pacing and ambulatory optimization of cardiac resynchronization therapy: results of the adaptive CRT trial.

نویسندگان

  • David O Martin
  • Bernd Lemke
  • David Birnie
  • Henry Krum
  • Kathy Lai-Fun Lee
  • Kazutaka Aonuma
  • Maurizio Gasparini
  • Randall C Starling
  • Goran Milasinovic
  • Tyson Rogers
  • Alex Sambelashvili
  • John Gorcsan
  • Mahmoud Houmsse
چکیده

BACKGROUND In patients with sinus rhythm and normal atrioventricular conduction, pacing only the left ventricle with appropriate atrioventricular delays can result in superior left ventricular and right ventricular function compared with standard biventricular (BiV) pacing. OBJECTIVE To evaluate a novel adaptive cardiac resynchronization therapy ((aCRT) algorithm for CRT pacing that provides automatic ambulatory selection between synchronized left ventricular or BiV pacing with dynamic optimization of atrioventricular and interventricular delays. METHODS Patients (n = 522) indicated for a CRT-defibrillator were randomized to aCRT vs echo-optimized BiV pacing (Echo) in a 2:1 ratio and followed at 1-, 3-, and 6-month postrandomization. RESULTS The study met all 3 noninferiority primary objectives: (1) the percentage of aCRT patients who improved in their clinical composite score at 6 months was at least as high in the aCRT arm as in the Echo arm (73.6% vs 72.5%, with a noninferiority margin of 12%; P = .0007); (2) aCRT and echo-optimized settings resulted in similar cardiac performance, as demonstrated by a high concordance correlation coefficient between aortic velocity time integrals at aCRT and Echo settings at randomization (concordance correlation coefficient = 0.93; 95% confidence interval 0.91-0.94) and at 6-month postrandomization (concordance correlation coefficient = 0.90; 95% confidence interval 0.87-0.92); and (3) aCRT did not result in inappropriate device settings. There were no significant differences between the arms with respect to heart failure events or ventricular arrhythmia episodes. Secondary end points showed similar benefit, and right-ventricular pacing was reduced by 44% in the aCRT arm. CONCLUSIONS The aCRT algorithm is safe and at least as effective as BiV pacing with comprehensive echocardiographic optimization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical response with adaptive CRT algorithm compared with CRT with echocardiography-optimized atrioventricular delay: a retrospective analysis of multicentre trials.

AIMS Adaptive cardiac resynchronization therapy (aCRT) is a novel algorithm for CRT pacing that provides automatic ambulatory selection between synchronized left ventricular (LV) or bi-ventricular (BiV) pacing and optimization of atrioventricular (AV) and inter-ventricular (VV) delays based on periodic measurement of intrinsic conduction. We aimed to compare the clinical response between aCRT a...

متن کامل

Cardiac resynchronization therapy pacemaker: critical appraisal of the adaptive CRT-P device

Cardiac resynchronization therapy (CRT) is an effective and well-established therapy for patients suffering with heart failure, left ventricular (LV) systolic dysfunction (ejection fraction ≤35%), and electrical dyssynchrony, demonstrated by a surface QRS duration of ≥120 ms. Patients undergoing treatment with CRT have shown significant improvement in functional class, quality of life, LV eject...

متن کامل

Trade-off between elimination of premature ventricular complexes and loss of synchronized left ventricular pacing improved cardiac function in a patient with heart failure

Synchronized left ventricular pacing (sLVP) via adaptive cardiac resynchronization therapy (aCRT) algorithm might enhance the efficacy of CRT. A 71-year-old female was admitted with the diagnosis of heart failure. Electrocardiograms revealed left bundle branch block with QRS width of 144 ms, and frequent premature ventricular complexes (PVCs). A CRT device was implanted, and sLVP via a CRT algo...

متن کامل

Clinical impact of increasing left ventricular pacing output in cardiac resynchronization therapy – the new optimization strategy

We report a patient who did not improve after standard optimization of atrioventricular and intraventricular pacing timing, but showed response to cardiac resynchronization therapy (CRT) after increasing left ventricular (LV) pacing output. Increasing LV pacing output is one of the useful optimization methods for CRT nonresponder.

متن کامل

An Overview of Current Cardiac Resynchronization Therapy.

UNLABELLED Cardiac resynchronization therapy (CRT) is currently an established device therapy for heart failure (HF) patients. Existing knowledge of implantation techniques, advances in device-based technologies and clinical trial experience have all significantly impacted this evolving therapy in recent years. This review article will address the updated CRT guidelines, and potentially new ind...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart rhythm

دوره 9 11  شماره 

صفحات  -

تاریخ انتشار 2012