Mechanical ventilation of the neonate: should we target volume or pressure?
نویسندگان
چکیده
For more than 40 years conventional mechanical ventilation has been used for the treatment of neonatal respiratory failure. Until relatively recently, this was accomplished with time-cycled pressure-limited ventilation, using intermittent mandatory ventilation. Earlier attempts at volume-targeted ventilation were largely ineffective because of technological limitations. The advent of microprocessor-based devices gives the clinician an option to choose either target variable to treat neonatal patients. This paper reviews the principles of each and the accumulated evidence.
منابع مشابه
Comparison of the effect of pressure support ventilation and volume assured pressure support ventilation on weaning patients off mechanical ventilation after cardiac surgery
Background: Weaning from mechanical ventilation in the intensive care unit is an important step in the treatment process. More patients in less than 6 hours after cardiac surgery can be separated from mechanical ventilation and extubated. However, 20-40% of patients after cardiac surgery, due to dysfunctional ventilator weaning response (DVWR), still remain under mechanical ventilation. Therefo...
متن کاملMechanical ventilation of the premature neonate.
Although the trend in the neonatal intensive care unit is to use noninvasive ventilation whenever possible, invasive ventilation is still often necessary for supporting pre-term neonates with lung disease. Many different ventilation modes and ventilation strategies are available to assist with the optimization of mechanical ventilation and prevention of ventilator-induced lung injury. Patient-...
متن کاملEvaluation of Troponin-T level in Neonate with Mechanical Ventilation
Introduction: Troponin- T is the best biological marker of heart injuries, that isn’t affected by sex, age, birth weight and gestational age. Myocardial damage in infancy is a risk factor eventual cardiac disease. This study carried out for cardiac evaluation of neonates with mechanical ventilation by Troponin T. Methods: This case-control study carried out on 60 infants that were admitte...
متن کاملبررسی مقایسهای روشهای PSV و SIMV در جدا کردن نوزادان از دستگاه تهویه مکانیکی
Background: The use of synchronized intermittent mandatory ventilation (SIMV) and pressure support ventilation (PSV) have been used for older children and adults. The purpose of this study was to compare PSV and SIMV modes in weaning from mechanical ventilation in neonate with respiratory failure. Methods: A randomized clinical trial study carried out in NICU ward of Valiasr hospital Imam Khom...
متن کاملAn Uncommon Cause of Neonatal Hypertension
Background: Adrenal hematoma is a very rare acquired cause of neonatal hypertension. In this study, we report a case of neonatal hypertension associated with adrenal hematoma. A male neonate was immediately transferred to our neonatal intensive care unit after delivery due to meconium aspiration. He needed to be on mechanical ventilation support. During his hospital stay, hospital records showe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 54 9 شماره
صفحات -
تاریخ انتشار 2009