Accuracy of the modified Hardinge approach in acetabular positioning.
نویسندگان
چکیده
BACKGROUND The surgical approach chosen for total hip arthroplasty (THA) may affect the positioning of the acetabular component. The purpose of this study was to examine the accuracy in orienting the acetabular component using the modified Hardinge approach. METHODS We used our institutional arthroplasty database to identify patients with primary, press-fit, hemispherical acetabular components of a metal-on-polyethylene THA performed between 2003 and 2011. Patients with radiographs obtained 1-3 years after the index procedure were included for measurement of anteversion and inclination angles. Acceptable values of anteversion and abduction angles were defined as 15° ± 10° and 40° ± 10°, respectively. RESULTS We identified 1241 patients from the database, and the modified Hardinge approach was used in 1010 of the patients included in our analysis. The acetabular component was anteverted in the acceptable zone in 54.1% of patients. The abduction angle was within the defined range in 79.2% of patients. Combined anteversion and abduction angles within the defined zone were present in 43.6% of patients. CONCLUSION Consistent with studies examining accuracy from other approaches, our study reveals that the modified Hardinge approach was only moderately accurate in positioning the acetabular component in the acceptable zone.
منابع مشابه
Salvaging unstable or recurrent dislocating total hip arthroplasty with the constrained acetabular component.
PURPOSE To review cases of implantation of constraining acetabular components for unstable or recurrent dislocating total hip arthroplasty at the Department of Orthopaedics, Concord Hospital, Sydney. METHODS A retrospective analysis was performed on prospectively collected data of 13 consecutively enrolled patients. RESULTS From 1989 to 2000, 13 constraining acetabular components were impla...
متن کاملAccuracy of Component Positioning in 2330 Total Hip Arthroplasties: A Comparative Analysis by Surgical Technique and Mode of Guidance
Lewinnek et al described a safe zone of acetabular component placement in Total Hip Arthroplasty (THA) to reduce complications. This safe zone is between 10-30 degrees of version and 30-50 degrees of inclination 1 . Callanan et al. reports only 53% of acetabular cups were within Lewinnek’s Safe Zone of optimal cup placement (62% within the abduction safe zone, 79% within the version safe zone)....
متن کاملA New Vision-Based and GPS-Signal-Independent Approach in Jamming Detection and UAV Absolute Positioning Assessment
The Unmanned Aerial Vehicles (UAV) positioning in the outdoor environment is usually done by the Global Positioning System (GPS). Due to the low power of the GPS signal at the earth surface, its performance disrupted in the contaminated environments with the jamming attacks. The UAV positioning and its accuracy using GPS will be degraded in the jamming attacks. A positioning error about tens of...
متن کاملIliac wing storage of femoral head autograft.
A safe, cheap, reliable method of bone storage is required for much arthroplasty revision surgery. We have screwed the femoral head taken from a primary hip arthroplasty to the ipsilateral iliac wing and, at a later date, harvested it for use in a contralateral revision hip arthroplasty. Case report. A 58-year-old woman with a history of bilateral hip degeneration had had a cemented double cup ...
متن کاملتعیین خودکار مختصات نجومی با استفاده از تصویربرداری زنیتی از ستارگان
Celestial positioning has been used for navigation purposes for many years. Stars as the extra-terrestrial benchmarks provide unique opportunity in absolute point positioning. However, astronomical field data acquisition and data processing of the collected data is very time-consuming. The advent of the Global Positioning System (GPS) nearly made the celestial positioning system obsolete. The n...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Canadian journal of surgery. Journal canadien de chirurgie
دوره 59 4 شماره
صفحات -
تاریخ انتشار 2016