Analysis on X-Ray Parameters of Exposure by Measuring X-Ray Tube Voltage and Time of Exposure

نویسنده

  • D.Tilak Raju
چکیده

---------------------------------------------------------------ABSTRACT-----------------------------------------------------One of the typical human diagnostic techniques is x-ray. The x-ray examination depends on the range of radiation given to the subject. The radiation from the xray depends primarily upon the x-ray tube current (mA) tube voltage (kVp) and exposure time (s). These parameters define the dosage. The aim of this work is to explore and analyze the x-ray exposure parameters levels which helps to diagnose and also has some hazardous health effects upon human exposure or the tissue which is being irradiated. Work has been carried out on people of different age groups ranging from 5yrs – 70 yrs. X -ray projections have been considered and the parameters influencing the radiography are being observed and are tabulated. Relations between the tube voltages (kVp) and exposure time (ms) have been closely observed and analysis have been done. This paper our reference levels for x-ray radiographic projections are carried as per the specifications of AERB and NRPB

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality assessment of conventional X-ray diagnostic equipment by measuring X-ray exposure and tube output parameters in Great Khorasan Province, Iran

Introduction: Regular implementation of quality control (QC) program in diagnostic X-ray facilities may affect both image quality and patient radiation dose due to the changes in exposure parameters. Therefore, this study aimed to investigate the status of randomly selected conventional radiographic X-ray devices installed in radiology centers of Great Khorasan Province, Iran, to produce the da...

متن کامل

The Evaluation of Conventional X-ray Exposure Parameters Including Tube Voltage and Exposure Time in Private and Governmental Hospitals of Lorestan Province, Iran

Introduction In radiography, dose and image quality are dependent on radiographic parameters. The problem is caused from incorrect use of radiography equipment and from the radiation exposure to patients much more than required. Therefore, the aim of this study was to implement a quality-control program to detect changes in exposure parameters, which may affect diagnosis or patient radiation do...

متن کامل

Performance Evaluation of Diagnostic X-Ray Equipment Regarding the Hospital Size in the Republic of Korea

  Introduction: The Republic of Korea has developed a national standard based on which diagnostic X-ray equipment must be tested every 3 years. Accordingly, the performance of X-ray equipment used in all hospitals is evaluated by national certification bodies in compliance with the safety management regulations for X-ray equipment. However, if the equipment i...

متن کامل

The Effect of Long-Term X-Ray Exposure on Human Lymphocyte

The aim of the paper is to investigate effects of long term x-ray exposure on the human lymphocyte, reactive lymphocyte parameters and morphology of lymphocytes in x-ray technicians at Kirkuk hospitals. The study included 54 apparently healthy male x-ray technicians were matched with another 54 apparently healthy control to show any alteration in the lymphocytes, reactive lymphocytes and morpho...

متن کامل

Calculation of Absorbed Glandular Dose using a FORTRAN Program Based on Monte Carlo X-ray Spectra in Mammography

Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014