Neutron transfer reactions induced by 8 Li on 9 Be
نویسندگان
چکیده
Angular distributions for the elastic scattering of 8 Li on 9 Be and the neutron transfer reactions Be have been measured with a 27 MeV 8 Li radioactive nuclear beam. Spectroscopic factors for 8 Li⊗n= 9 Li and 7 Li⊗n= 8 Li bound systems were obtained from the comparison between the experimental differential cross section and finite-range DWBA calculations with the code FRESCO. The spectroscopic factors obtained are compared to shell model calculations and to other experimental values from (d,p) reactions. Using the present values for the spectroscopic factor, cross sections for the direct neutron-capture reactions 7 Li(n,γ) 8 Li and 8 Li(n,γ) 9 Li were calculated in the framework of a potential model.
منابع مشابه
طراحی و بهینهسازی طیف نوترونی برای درمان تومورهای عمیق مغزی به روش BNCT با کاهش آسیب رسیده به پوست
Boron neutron capture therapy (BNCT) is an effective method for treatment of deep seated brain tumors. This method consists of two stages: injection of boron compound in the patient body, and then irradiation of the region tumors with the neutron beam. It allows for delivery of high linear energy transfer (LET) radiation (particles 4He and 7Li nuclei) to tumors at the cellular level whilst avoi...
متن کاملModification of 10 cGy neutron or gamma-rays induced chromosomal damages by hyperthermia: an in vitro study
Background: To evaluate the effects of hyperthermia (HT) on the frequency of chromosomal aberrations induced by a low dose of neutron or γ-rays in human peripheral blood lymphocytes. Materials and Methods: Blood samples were exposed to HT (41.5°C for 30 and 60min, 43°C for 15 and 30min), 10 cGy neutron or γ-rays, HT + neutron/γ, and neutron/γ + HT. After standard cell culture, harvestin...
متن کاملاندازهگیری دز گامای ایجاد شده توسط نوترونهای حرارتی در دزسنجTLD-700
Neutron response Induced in Thermoluminescence Dosimeter TLD-700 chips due to reactions of thermal neutrons with slab phantom and Badge Dosimeter TLD-600,700 materials in a neutron-gamma mixed field was measured. Using the linear relationship between thermal neutron fluence and the thermal neutrons induced TL response with slab phantom, Badge-TLD Materials, an empirical relationship was introdu...
متن کاملExperimental and Monte Carlo studies on the response of CR-39 detectors to Am-Be neutron spectrum
Background: The Poly-Allyl Diglycol Carbonate (PADC) detector is of particular interest for development of a fast neutron dosimeter. Fast neutrons interact with the constituents of the CR-39 detector and produce H, C and O recoils, as well as (n, α) reaction. These neutron- induced charged particles contribute towards the response of CR-39 detectors. Material and Methods: Electrochemical...
متن کاملApoptosis through Bcl-2/Bax and Cleaved Caspase Up-Regulation in Melanoma Treated by Boron Neutron Capture Therapy
Boron neutron capture therapy (BNCT) is a binary treatment involving selective accumulation of boron carriers in a tumor followed by irradiation with a thermal or epithermal neutron beam. The neutron capture reaction with a boron-10 nucleus yields high linear energy transfer (LET) particles, alpha and (7)Li, with a range of 5 to 9 µm. These particles can only travel very short distances and rel...
متن کامل